Assessment of unilateral afferent pupillary defects by pupillography.
نویسندگان
چکیده
A pupillographic technique, an adaptation of the swinging light test, is described for the measurement of unilateral afferent pupillary defects. In normal persons it yielded accurate, reproducible estimates of the magnitude of artificial afferent defects made with neutral filters of 1 to 4 log units density. In 15 studies on 8 patients with unilateral optic neuritis and 2 with unilateral compressive lesions the measured afferent pupillary defects correlated closely with both visual acuity and visual threshold deficits. Measurement of the pupillary defect underestimated severe degrees of impairment revealed by visual threshold determination. Discrepancies between pupillary defect and visual acuity were observed in the 2 patients with compressive lesions and in 1 patient who had a central scotoma 4 months after an attack of optic neuritis.
منابع مشابه
Pupillography of automated swinging flashlight test in amblyopia
Relative afferent pupillary defects (RAPDs) in amblyopia have been reported, and it is widely accepted that amblyopes can have an RAPD. We investigated whether or not this could be confirmed by the use of binocular pupillography. We examined twelve patients (6 males and 6 females, aged 7-57 years) with unilateral amblyopia associated with anisometropia and/or strabismus, using binocular infrare...
متن کاملThe usefulness of a new method of testing for a relative afferent pupillary defect in patients with ocular hypertension and glaucoma.
PURPOSE To evaluate the validity of different methods of relative afferent pupillary defect (RAPD) detection and assess the usefulness of detecting an RAPD in glaucoma patients. METHODS For this prospective observational study, we enrolled 70 of 153 consecutive glaucoma patients coming for examination. Exclusion criteria were cloudy corneas, recent surgery, fixed pupils, and other diseases pr...
متن کاملOrigin of the relative afferent pupillary defect in optic tract lesions.
OBJECTIVE To determine the percent decussation of pupil input fibers in humans and to explain the size and range of the log unit relative afferent pupillary defect (RAPD) in patients with optic tract lesions. DESIGN Experimental study. PARTICIPANTS AND CONTROLS Five patients with a unilateral optic tract lesion. METHODS The pupil response from light stimulation of the nasal hemifield, tem...
متن کاملAssociation between a relative afferent pupillary defect using pupillography and inner retinal atrophy in optic nerve disease
PURPOSE The aim of this study was to compare the asymmetrical light reflex of the control subjects and patients with optic nerve disease and to evaluate the relationships among the relative afferent pupillary defect (RAPD), visual acuity (VA), central critical fusion frequency (CFF), ganglion cell complex thickness (GCCT), and circumpapillary retinal nerve fiber layer thickness (cpRNFLT) using ...
متن کاملPortable pupillography of the swinging flashlight test to detect afferent pupillary defects.
OBJECTIVE To investigate the ability of a portable, personal computer-driven, pupillometer to record the pupillary response curve during the swinging flashlight test. Also, to determine whether these response curves can be used to identify and quantify relative asymmetry in the pupillary light reflex between eyes in healthy volunteers with simulated afferent pupil defects (APDs) and patients wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 63 3 شماره
صفحات -
تاریخ انتشار 1979