Use of Electrical Impedance Tomography to Monitor Regional Cerebral Edema during Clinical Dehydration Treatment
نویسندگان
چکیده
OBJECTIVE Variations of conductive fluid content in brain tissue (e.g. cerebral edema) change tissue impedance and can potentially be measured by Electrical Impedance Tomography (EIT), an emerging medical imaging technique. The objective of this work is to establish the feasibility of using EIT as an imaging tool for monitoring brain fluid content. DESIGN a prospective study. SETTING In this study EIT was used, for the first time, to monitor variations in cerebral fluid content in a clinical model with patients undergoing clinical dehydration treatment. The EIT system was developed in house and its imaging sensitivity and spatial resolution were evaluated on a saline-filled tank. PATIENTS 23 patients with brain edema. INTERVENTIONS The patients were continuously imaged by EIT for two hours after initiation of dehydration treatment using 0.5 g/kg intravenous infusion of mannitol for 20 minutes. MEASUREMENT AND MAIN RESULTS Overall impedance across the brain increased significantly before and after mannitol dehydration treatment (p = 0.0027). Of the all 23 patients, 14 showed high-level impedance increase and maintained this around 4 hours after the dehydration treatment whereas the other 9 also showed great impedance gain during the treatment but it gradually decreased after the treatment. Further analysis of the regions of interest in the EIT images revealed that diseased regions, identified on corresponding CT images, showed significantly less impedance changes than normal regions during the monitoring period, indicating variations in different patients' responses to such treatment. CONCLUSIONS EIT shows potential promise as an imaging tool for real-time and non-invasive monitoring of brain edema patients.
منابع مشابه
Applications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملImprovement ability of EIT for Thermal monitoring during Thermal Therapy by gold nanoparticles
Introduction: To prevention the healthy tissues from irreversible damages, monitoring the temperature variation of healthy tissues is critical parameter during thermal therapies. Electrical impedance tomography (EIT) is considered as a real time imaging modality for monitoring the temperature but researches show that it suffers from low temperature resolution. In this study usi...
متن کاملAssessment of regional ventilation in acute respiratory distress syndrome by electrical impedance tomography.
Mechanical ventilation in acute respiratory distress syndrome (ARDS) incurs a risk of ventilator-associated lung injury (VALI) from inhomogeneous conditions and different properties of dependent and non-dependent lung regions at risk of atelectasis and overdistension, respectively. Electrical impedance tomography (EIT) offers regional ventilation assessment to optimise treatment with mechanical...
متن کاملMeasurement of brain edema by noninvasive cerebral electrical impedance in patients with massive hemispheric cerebral infarction.
BACKGROUND Malignant cerebral infarction often occurs in patients with massive cerebral infarction. Monitoring brain edema is therefore helpful to make correct clinical decisions. Our previous studies have confirmed that cerebral electrical impedance (CEI) can sensitively reflect the brain edema after stroke. METHODS The CEI was measured consecutively by a noninvasive brain edema monitor in 6...
متن کاملMeasurement of lung function using Electrical Impedance Tomography (EIT) during mechanical ventilation
The consistency of regional lung density measurements as estimated by Electrical Impedance Tomography (EIT), in eleven patients supported by a mechanical ventilator, was validated to verify the feasibility of its use in intensive care medicine. There were significant differences in regional lung densities between the normal lung and diseased lungs associated with pneumonia, atelectasis and pleu...