Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: a comparative biomechanical study.
نویسندگان
چکیده
BACKGROUND Optimization of anterior cruciate ligament (ACL) fixation is desired to improve graft healing. New soft tissue cortical suspension devices for femoral tunnel fixation should be biomechanically evaluated. HYPOTHESIS All femoral fixation devices would prevent a clinically significant amount of displacement and support loads significantly larger than in situ forces experienced by the ACL during early rehabilitation. STUDY DESIGN Controlled laboratory study. METHODS Four cortical soft tissue ACL graft suspension devices were tested under cyclic and pull-to-failure loading conditions in both an isolated device-only setup and as a complete bone-device-tendon construct in porcine femurs using a tensile testing machine. RESULTS There were significant differences in the ultimate failure loads among the devices. The highest ultimate failure loads when tested as a construct were observed for the XO Button (1748 N), followed by the Endobutton CL (1456 N), ToggleLoc with ZipLoop (1334 N), and TightRope RT (859 N). Cyclic displacement after 1000 cycles during isolated device testing was less than 1 mm for all devices. Cyclic displacements after 1000 cycles in the porcine construct were 1.88 mm, 2.74 mm, 3.34 mm, and 1.82 mm for the Endobutton, TightRope, ToggleLoc, and XO Button, respectively; all were significantly different from each other except when the Endobutton was compared with the XO Button. The ToggleLoc exceeded the 3.0-mm displacement threshold defined as a clinical failure. The most displacement occurred during the first cycle, especially for the adjustable-length loop devices. Stiffness reapproximated the native ACL stiffness for all constructs. CONCLUSION The Endobutton, TightRope, and XO Button have the necessary biomechanical properties with regard to ultimate failure strength, displacement, and stiffness for initial fixation of soft tissue grafts in the femoral tunnel for ACL reconstruction. The ToggleLoc had sufficient ultimate failure strength but crossed our 3.0-mm clinical failure threshold for cyclic displacement. Although this study was not designed to compare fixed and adjustable-length loop devices, it was noted that both fixed-loop devices allowed less cyclic displacement and initial displacement. CLINICAL RELEVANCE Adjustable-length loop devices may need to be retensioned after cycling the knee and fixing the tibial side to account for the increased initial displacement seen with these devices.
منابع مشابه
Comparison of Outcomes of Two Femoral Fixation Devices in Hamstring Anterior Cruciate Ligament Reconstruction
BACKGROUND Tear of the anterior cruciate ligament (ACL) is a common ligamentous injury of the knee. Reconstruction of this ligament is often required to restore functional stability of the knee. Outcome of ACL reconstruction is significantly affected by how the graft is fixed to the bone. This study is to determine if there is a different clinical outcome after cortical versus cortical-cancello...
متن کاملFemoral Aperture Fixation Improves Anterior Cruciate Ligament Graft Function When Added to Cortical Suspensory Fixation
BACKGROUND Recommendations for bone tunnel placement during anterior cruciate ligament (ACL) reconstruction have become more precise. However, these recommendations differ neither with the choice of graft nor with the method of fixation used. The influence of the method of femoral fixation used on the biomechanical function of a soft tissue ACL graft remains unknown. HYPOTHESIS Our null hypot...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملComparison of Clinical Outcomes between Different Femoral Tunnel Positions after Anterior Cruciate Ligament Reconstruction Surgery
Background: It has been shown that the proper placement of ACL graft during the ACL reconstruction surgery significantly improves the clinical outcomes. This study investigated whether a change in the femoral tunnel position in both axial and coronal planes can significantly alter the postoperative functional and clinical outcomes of the patients. Methods: This comparative, retrospective, singl...
متن کاملArthroscopic Technique to Reduce Suture Button Migration During Anterior Cruciate Ligament Reconstruction Procedure
Suture button-based femoral cortical suspension constructs of anterior cruciate ligament grafts can facilitate a fast and secure fixation. However, there are several case reports showing button malpositioning resulting from the inability to visualize the "flipped" button. Many current surgical techniques do not allow direct visualization of EndoButtons (Smith & Nephew, Andover, MA) in their fin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of sports medicine
دوره 41 2 شماره
صفحات -
تاریخ انتشار 2013