Management of paediatric tibial fractures using two types of circular external fixator: Taylor spatial frame and Ilizarov circular fixator
نویسندگان
چکیده
BACKGROUND The use of circular fixators for the treatment of tibial fractures is well established in the literature. The aim of this study was to compare the Ilizarov circular fixator (ICF) with the Taylor spatial frame (TSF) in terms of treatment results in consecutive patients with tibial fractures that required operative management. METHOD A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, time duration in frame, healing time and complications of treatment. The minimum follow-up was 24 months. RESULTS Ten patients were treated with ICF between 2000 and 2005, while 15 patients have been treated with TSF since 2005. Two of the 10 treated with ICF and 5 of the 15 treated with TSF were open fractures. All patients went on to achieve complete union. Mean duration in the frame was 12.7 weeks for ICF and 14.8 weeks for the TSF group. Two patients in the TSF group had delayed union and required additional procedures including adjustment of fixator and bone grafting. There was one malunion in the TSF group that required osteotomy and reapplication of frame. There were seven and nine pin-site infections in the ICF and TSF groups, respectively, all of which responded to antibiotics. There were no refractures in either group. CONCLUSION In an appropriate patient, both types of circular fixator are equally effective but have different characteristics, with TSF allowing for postoperative deformity correction. Of concern are the two cases of delayed union in the TSF group, all in patients with high-energy injuries. We feel another larger study is required to provide further clarity in this matter. LEVEL OF EVIDENCE Level II-comparative study.
منابع مشابه
Cost implications of the physiotherapy management of complex tibial fractures treated with circular frames
Seventy-three consecutive patients with complex tibial fractures treated with an Ilizarov frame or Taylor Spatial Frame received physiotherapy between April 2008 and April 2010. Data were collected prospectively, and physiotherapy input was recorded (in minutes) for the patients identified. This included treatment received as an inpatient as well as an outpatient. The data were categorized for ...
متن کاملManagement of distal tibial intra-articular fractures with circular external fixation
The treatment of tibial plafond fractures requires careful management of the soft tissue envelope, reconstruction of the articular surface and stable fixation with minimal additional damage. Thirty cases of AO type 43 C tibial fractures were treated by transosseous osteosynthesis (Ilizarov technique). The external fixator constructs used were Ilizarov (Transosseous osteosynthesis: theoretical a...
متن کاملIlizarov Versus AO External Fixator for the Treatment of Tibia Open Fractures
BACKGROUND In developing countries, Ilizarov or AO external fixator is usually used for treatment of tibial open fractures. The purpose of this study was to compare the efficacy of these two methods for treatment of tibial open fractures. METHODS From April 2002 to April 2010, 120 patients with open tibial fractures admitted to the Department of Orthopedics of Babol University of Medical Scie...
متن کاملTreatment of ipsilateral high energy tibial plateau and calcaneal fractures by a circular wire fixator: a case report
INTRODUCTION High energy tibial plateau fractures along with calcaneal fractures individually produce several challenges for the orthopaedic surgeon. The principles of bony reconstruction include anatomic reduction and rigid internal fixation of intra-articular fractures and accurate restoration of the coronal, sagittal and transverse mechanical axes. Due to the tenuous nature of the soft tissu...
متن کاملMechanical rigidity of the Ortho-SUV frame compared to the Ilizarov frame in the correction of femoral deformity
The Ortho-SUV frame (OSF) is a novel hexapod circular external fixator which draws upon the innovation of the Ilizarov method and the advantages of hexapod construction in the three-dimensional control of bone segments. Stability of fixation is critical to the success or failure of an external circular fixator for fracture or osteotomy healing. In vitro biomechanical modelling study was perform...
متن کامل