Dosimetric analysis of I, I and I in thyroid follicle models
نویسندگان
چکیده
Background: Radioiodine is routinely used or proposed for diagnostic and therapeutic purposes: I, I and I for diagnostics and I and I for therapy. When radioiodine-labelled pharmaceuticals are administered to the body, radioiodide might be released into the circulation and taken up by the thyroid gland, which may then be an organ at risk. The aim of this study was to compare dosimetric properties for I, I and I in previously developed thyroid models for man, rat and mouse. Methods: Dosimetric calculations were performed using the Monte Carlo code MCNPX 2.6.0 and nuclear decay data from ICRP 107. Only the non-radiative transitions in the decays were considered. The S value was determined for the cell nuclei in species-specific thyroid follicle models for mouse, rat and man for different spatial distributions of radioiodine. Results: For the species-specific single follicle models with radioiodine homogeneously within the follicle lumen, the highest S value came from I, with the largest contribution from the β particles. When radioiodine was homogeneously distributed within the follicle cells or the follicle cell nucleus, the highest contribution originated from I, about two times higher than I, with the largest contribution from the Auger electrons. The mean absorbed dose calculated for our human thyroid multiple follicle model, assuming homogenous distribution of for I, I, or I within the follicle lumens and follicle cells, was 9%, 18% and 4% higher, respectively, compared with the mean absorbed dose according to Medical Internal Radiation Dose (MIRD) formalism and nuclear decay data. When radioiodine was homogeneously distributed in the follicle lumens, our calculations gave up to 90% lower mean absorbed dose for I compared to MIRD (20% lower for I, and 2% lower for I). Conclusions: This study clearly demonstrates the importance of using more detailed dosimetric methods and models than MIRD formalism for radioiodine, especially I and I, in the thyroid. For radioiodine homogeneously distributed in the follicle lumens our calculations for the human multiple follicle models gave up to 90% lower mean absorbed dose compared with MIRD formalism.
منابع مشابه
Dosimetric analysis of 123I, 125I and 131I in thyroid follicle models
BACKGROUND RADIOIODINE IS ROUTINELY USED OR PROPOSED FOR DIAGNOSTIC AND THERAPEUTIC PURPOSES: (123)I, (125)I and (131)I for diagnostics and (125)I and (131)I for therapy. When radioiodine-labelled pharmaceuticals are administered to the body, radioiodide might be released into the circulation and taken up by the thyroid gland, which may then be an organ at risk. The aim of this study was to com...
متن کاملComparison of Absorbed Fraction of Gamma and Beta Rays of I-124 and I-131radio-Isotopes in Thyroid Gland with Monte Carlo Simulation
I131 is a famous radio-iodine isotope in use for diagnosis and treatment of hyper functioning and cancerous thyroid gland. It is a nuclear reactor product; however nuclear reactor may be unavailable in some areas. Replacement by I-124 may be possible, another iodine isotope producible by cyclotron; a system more available than reactor. Here absorbed fraction of Gamma and Beta rays of...
متن کاملComparison of Absorbed Fraction of Gamma and Beta Rays of I-124 and I-131radio-Isotopes in Thyroid Gland with Monte Carlo Simulation
I131 is a famous radio-iodine isotope in use for diagnosis and treatment of hyper functioning and cancerous thyroid gland. It is a nuclear reactor product; however nuclear reactor may be unavailable in some areas. Replacement by I-124 may be possible, another iodine isotope producible by cyclotron; a system more available than reactor. Here absorbed fraction of Gamma and Beta rays of...
متن کاملEstimation of dosimetric parameters of I-125 brachytherapy source model 6711 using GATE8.1 code
Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...
متن کاملDosimetric Parameters Estimation of I-125 Brachytherapy Source in fat phantom using GATE8.0 code
Introduction: Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated, are placed as close as possible to the tumor site or inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule to create optimal treatment plant. In this way, dosimetric parameters are...
متن کامل