Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices

نویسندگان

  • Lays Magalhães Braga
  • Gustavo Faibischew Prado
  • Iracema Ioco Kikuchi Umeda
  • Tatiana Satie Kawauchi
  • Adriana Marques Fróes Taboada
  • Raymundo Soares Azevedo
  • Horacio Gomes Pereira Filho
  • César José Grupi
  • Hayala Cristina Cavenague Souza
  • Dalmo Antônio Ribeiro Moreira
  • Naomi Kondo Nakagawa
چکیده

Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86<CCC<0.99] based on Holter at rest, during 6MW and recovery. At higher rates, a small effect in increasing differences between Holter and Polar in R-R intervals was observed. In conclusion, our study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Exercise Training on Heart Rate Variability in Patients with Heart Failure After Percutaneous Coronary Intervention

Background: This study aims to evaluate the effect of exercise training on heart rate variability (HRV) and to determine the correlation between parameters of HRV and the ejection fraction in patients with heart failure after percutaneous coronary intervention.Material and Methods: Fifty patients with left ventricular ejection fraction ≤ 40% undergone percutaneous coronary intervention were r...

متن کامل

The reproducibility and sensitivity of the 6-min walk test in elderly patients with chronic heart failure.

AIMS The 6-min walk test (6-MWT) is used to estimate functional capacity. However, in elderly patients with chronic heart failure (CHF): (i) 1 year reproducibility of the 6-MWT; (ii) sensitivity of the 6-MWT to self-perceived changes in symptoms of heart failure; and (iii) implications for patient numbers required for studies using the 6-MWT as an endpoint have not been described. METHODS AND...

متن کامل

Decreased Variability of the 6-Minute Walk Test by Heart Rate Correction in Patients with Neuromuscular Disease

OBJECTIVE The 6-minute walk test is widely used to assess functional status in neurological disorders. However, the test is subject to great inter-test variability due to fluctuating motivation, fatigue and learning effects. We investigated whether inter-test variability of the 6MWT can be reduced by heart rate correction. METHODS Sixteen patients with neuromuscular diseases, including Facios...

متن کامل

Heart rate variability reproducibility during exercise.

The use of heart rate variability (HRV) parameters during exercise is not supported by appropriate reliability studies. In 80 healthy adults, ECG was recorded during three 6 min bouts of exercise, separated by 6 min of unloaded cycling. Two bouts were at a moderate intensity while the final bout was at a heavy exercise intensity. This protocol was repeated under the same conditions on three occ...

متن کامل

Correlation between low T3 syndrome and mortality rate in patients with systolic heart failure

Introduction: This study was performed to evaluate the prevalence of low T3 syndrome among patients with heart failure and to assess the correlation between decreased level of tri iodothyronin (T3) with mortality rate. Methods: In a prospective cross-sectional study, 91 patients with systolic heart failure were admitted to Mohammadi hospital in Bandar Abbas in 2008.Thyroid function test w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016