Comparison of nonenhanced MR angiographic subtraction techniques for infragenual arteries at 1.5 T: a preliminary study.
نویسندگان
چکیده
PURPOSE To evaluate diagnostic performance of three nonenhanced methods: variable-refocusing-flip angle (FA) fast spin-echo (SE)-based magnetic resonance (MR) angiography (variable FA MR) and constant-refocusing-FA fast SE-based MR angiography (constant-FA MR) and flow-sensitive dephasing (FSD)-prepared steady-state free precession MR angiography (FSD MR) for calf arteries, with dual-injection three-station contrast material-enhanced MR angiography (gadolinium-enhanced MR) as reference. MATERIALS AND METHODS This prospective study was institutional review board approved and HIPAA compliant, with informed consent. Twenty-one patients (13 men, eight women; mean age, 62.6 years) underwent calf-station variable-FA MR, constant-FA MR, and FSD MR at 1.5 T, with gadolinium-enhanced MR as reference. Image quality and stenosis severity were assessed in 13 segments per leg by two radiologists blinded to clinical data. Combined constant-FA MR and FSD MR reading was also performed. Methods were compared (logistic regression for correlated data) for diagnostic accuracy. RESULTS Of 546 arterial segments, 148 (27.1%) had a hemodynamically significant (≥ 50%) stenosis. Image quality was satisfactory for all nonenhanced MR sequences. FSD MR was significantly superior to both other sequences (P < .0001), with 5-cm smaller field of view; 9.6% variable-FA MR, 9.6% constant-FA MR, and 0% FSD MR segmental evaluations had nondiagnostic image quality scores, mainly from high diastolic flow (variable-FA MR) and motion artifact (constant-FA MR). Stenosis sensitivity and specificity were highest for FSD MR (80.3% and 81.7%, respectively), compared with those for constant-FA MR (72.3%, P = .086; and 81.8%, P = .96) and variable-FA MR (75.9%, P = .54; and 75.6%, P = .22). Combined constant-FA MR and FSD MR had superior sensitivity (81.8%) and specificity (88.3%) compared with constant-FA MR (P = .0076), variable-FA MR (P = .0044), and FSD MR (P = .0013). All sequences had an excellent negative predictive value (NPV): 93.2%, constant-FA MR; 94.7%, variable-FA MR; 91.7%, FSD MR; and 92.9%, combined constant-FA MR and FSD MR. CONCLUSION At 1.5 T, all evaluated nonenhanced MR angiographic methods demonstrated satisfactory image quality and excellent NPV for hemodynamically significant stenosis. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120859/-/DC1.
منابع مشابه
ECG-gated nonenhanced 3D steady-state free precession MR angiography in assessment of transplant renal arteries: comparison with DSA.
PURPOSE To evaluate noncontrast material-enhanced steady-state free precession (SSFP) magnetic resonance (MR) angiography in the assessment of transplant renal arteries (RAs) by using digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS This prospective study was approved by the institutional review board; written informed consent was obtained from all partic...
متن کاملVascularization of head and neck paragangliomas: comparison of three MR angiographic techniques with digital subtraction angiography.
BACKGROUND AND PURPOSE MR angiography of the head and neck region has been studied widely, but few studies have been performed concerning the efficacy of MR angiography for the identification of the specific vascular supply of the highly vascular head and neck paragangliomas. In this study, we compared three MR angiography techniques with respect to visualization of branch arteries in the neck ...
متن کاملNonenhanced MR angiography.
While nonenhanced magnetic resonance (MR) angiographic methods have been available since the earliest days of MR imaging, prolonged acquisition times and image artifacts have generally limited their use in favor of gadolinium-enhanced MR angiographic techniques. However, the combination of recent technical advances and new concerns about the safety of gadolinium-based contrast agents has spurre...
متن کاملAccuracy of contrast-enhanced MR angiography in predicting angiographic stenosis of the internal carotid artery: linear regression analysis.
BACKGROUND AND PURPOSE We sought to assess whether contrast-enhanced MR angiography is able to predict the degree of angiographic stenosis of the internal carotid artery within a clinically acceptable margin of error, thereby decreasing the need for angiography. In addition, we sought to assess whether adding ultrasound peak systolic velocity (PSV) as an additional regressor improves the accura...
متن کامل3D MR angiography of renal arteries: comparison of volume rendering and maximum intensity projection algorithms.
PURPOSE To compare volume rendering (VR) and maximum intensity projection (MIP) as postprocessing techniques of magnetic resonance (MR) angiography for detection and quantification of renal artery stenosis. MATERIALS AND METHODS Twenty-seven patients underwent three-dimensional contrast material-enhanced MR angiography of the renal arteries with a 1.5-T imager. For each renal artery, targeted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 267 1 شماره
صفحات -
تاریخ انتشار 2013