Evaluation of the Recombigen HIV-1 Latex Agglutination Test.

نویسندگان

  • C A Starkey
  • B Yen-Lieberman
  • M R Proffitt
چکیده

The Recombigen HIV-1 Latex Agglutination (LA) Test was recently licensed by the U.S. Food and Drug Administration for use as a rapid screening assay for human immunodeficiency virus type 1 (HIV-1) antibodies. However, its performance in various settings and in different populations has not been firmly established. Consequently, we evaluated the test in the Cleveland Clinic Retrovirus Laboratory, a regional reference laboratory for HIV diagnostic testing and a testing laboratory for the Ohio Department of Health Anonymous HIV Testing and Counseling Program. Serum samples from 93 individuals presumed to be at high risk for HIV infection were evaluated. The sera were initially tested for HIV antibodies by enzyme-linked immunosorbent assay (ELISA). All repeatedly reactive sera were subjected to confirmatory Western blot (WB; immunoblot) testing. Of 97 serum specimens tested (5 were from one seroconverter), 44 were repeatedly reactive by ELISA and 53 were nonreactive. Of the reactive serum specimens, 31 were confirmed positive and 12 were indeterminate by WB. All of the sera were coded and then retested by the LA test. Of 53 serum specimens nonreactive by ELISA, 51 were also nonreactive in the LA test. Of the 44 serum specimens reactive by ELISA, 16 were nonreactive by LA; however, 3 of the latter were WB positive. No serum specimen with an ELISA ratio (specimen optical density/cutoff optical density) of less than 2.1 scored reactive in the LA test. The LA test was positive for only two of five consecutive serum specimens from a seroconverter despite the fact that all but the earliest of these were ELISA reactive and WB positive. Although the LA test appears to be an adequate first-line screening test when appropriately used according to the directions of the manufacturer, our data suggest that occasional sera with low levels of reactivity by ELISA may not be readily detected as reactive by the LA test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and evaluation of latex agglutination technique for diagnosis and seroepidemiological studies of visceral leishmaniasis

in this study which has been carried out from 1996 until 1997 soluble latex agglutination antigen was prepared from L, donovani,sudan(s-1) by culturing in special media,harvesting,and later solubilizing by freezing and thawing.the antigen were futher prepared by high speed centrifugation.after measurement of the protein (lowry method) concentration of the antigen was set at 2.2 mg/ml,the antige...

متن کامل

Development of a Latex Agglutination Method for Diagnosis of Rotavirus Infections

Background: Rotavirus is a major cause of morbidity and mortality among children with gastroenteritis. Since the discovery of rotaviruses, several techniques have been used for their laboratory diagnosis; those included Electron Microscopy (EM) and enzyme immunoassay. These methods, however, are expensive and not readily available everywhere. We have developed a technique which can be used for ...

متن کامل

Evaluation of a Latex Agglutination Test for Detection of Antibodies to Rubella Virus in Selected Sera

A new latex agglutination test for rubella virus was used to test sera with a hemagglutination inhibition titer of -8 (97 specimens) or >256 (158 specimens). Maximum latex agglutination test sensitivity was achieved when low-titer sera were tested undiluted and high-titer sera were diluted (1:10). A modification of the protocol of the manufacturer resulted in a latex agglutination-hemagglutinat...

متن کامل

Conventional Rapid Latex Agglutination in Estimation of von Willebrand Factor: Method Revisited and Potential Clinical Applications

Measurement of von Willebrand factor antigen (VWF : Ag) levels is usually performed in a specialised laboratory which limits its application in routine clinical practice. So far, no commercial rapid test kit is available for VWF : Ag estimation. This paper discusses the technical aspect of latex agglutination method which was established to suit the purpose of estimating von Willebrand factor (...

متن کامل

Evaluation of a latex agglutination test for detection of antibodies to rubella virus in selected sera.

A new latex agglutination test for rubella virus was used to test sera with a hemagglutination inhibition titer of less than or equal to 8 (97 specimens) or greater than or equal to 256 (158 specimens). Maximum latex agglutination test sensitivity was achieved when low-titer sera were tested undiluted and high-titer sera were diluted (1:10). A modification of the protocol of the manufacturer re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 1990