Validation of parametric methods for [11C]PE2I positron emission tomography
نویسندگان
چکیده
OBJECTIVES The radioligand [(11)C]PE2I is highly selective for dopamine transporter (DAT) and can be used in vivo for investigation of changes in DAT concentration, progression of disease and validation of treatment using positron emission tomography (PET). DAT is an important protein for regulation of central dopamine concentration and DAT deficiency has been associated with several neurodegenerative and neuropsychiatric disorders. Accurate parametric images are a prerequisite for clinical application of [(11)C]PE2I. The purpose of this study was to evaluate different methods for producing [(11)C]PE2I parametric images, showing binding potential (BPND) and relative delivery (R1) at the voxel level, using clinical data as well as simulations. METHODS Investigations were made in twelve subjects either with social anxiety disorder (n=6) or parkinsonian syndrome (n=6), each receiving an 80 min dynamic PET scan. All subjects underwent a T1-weighted MRI scan which was co-registered to the PET images and used for definition of regions of interest using a probabilistic template (PVElab). Two basis function implementations (receptor parametric mapping: RPM, RPM2) of the simplified reference tissue model (SRTM) and three multilinear reference tissue models (MRTMo, MRTM and MRTM2) were used for computation of parametric BPND and R1 images. In addition, reference Logan and standard uptake value ratio (SUVr) were investigated. Evaluations of BPND and R1 images were performed using linear regression to compare the parametric methods to region-based analyses with SRTM and cerebellar gray matter as reference region. Accuracy and precision of each method were assessed by simulations. RESULTS Correlation and slope of linear regression between parametric and region-based BPND and R1 values in both striatum and extra-striatal regions were optimal for RPM (R(2)=0.99 for both BPND and R1; slopes 0.99 and 0.98 for BPND and R1, respectively, in striatum). In addition, accuracy and precision were best for RPM and RPM2. CONCLUSION The basis function methods provided more robust estimations of the parameters compared to the other models and performed best in simulations. RPM, a basis function implementation of SRTM, is the preferred method for voxel level analysis of [(11)C]PE2I PET studies.
منابع مشابه
Development of a clinically feasible [11C]PE2I PET method for differential diagnosis of parkinsonism using reduced scan duration and automated reference region extraction.
[11C]PE2I is a highly selective dopamine transporter PET ligand. Parametric images based on dynamic [11C]PE2I scans, showing dopamine transporter availability (BPND) and relative cerebral blood flow (R1), can be used in differential diagnosis of parkinsonism. This work aimed to investigate a shortened scan duration and automated generation of parametric images which are two prerequisites for ro...
متن کاملAnatomic and biochemical correlates of the dopamine transporter ligand 11C-PE2I in normal and parkinsonian primates: comparison with 6-[18F]fluoro-L-dopa.
Positron emission tomography (PET) coupled to 6-[18F]Fluoro-L-Dopa (18F-Dopa) remains the gold standard for assessing dysfunctionality concerning the dopaminergic nigrostriatal pathway in Parkinson's disease and related disorders. The use of ligands of the dopamine transporters (DAT) is an attractive alternative target; consequently, the current aim was to validate one of them, 11C-PE2I, using ...
متن کاملCalculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit
Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...
متن کاملTowards Clinical Implementation of Dynamic Positron Emission Tomography in Neurodegenerative Diseases
Jonasson, M. 2018. Towards Clinical Implementation of Dynamic Positron Emission Tomography in Neurodegenerative Diseases. Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine 1429. 55 pp. Uppsala: Acta Universitatis Upsaliensis. ISBN 978-91-513-0238-6. Alzheimer’s disease (AD) and Parkinson’s disease (PD) are the two most common neurodegenerative disorders world...
متن کاملLinearized reference tissue parametric imaging methods: application to [11C]DASB positron emission tomography studies of the serotonin transporter in human brain.
SUMMARY The authors developed and applied two new linearized reference tissue models for parametric images of binding potential (BP) and relative delivery (R1) for [11C]DASB positron emission tomography imaging of serotonin transporters in human brain. The original multilinear reference tissue model (MRTM(O)) was modified (MRTM) and used to estimate a clearance rate (k'2) from the cerebellum (r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 74 شماره
صفحات -
تاریخ انتشار 2013