Comparative evaluation of efficacy and safety of ophthalmic viscosurgical devices in phacoemulsification [ISRCTN34957881]
نویسندگان
چکیده
BACKGROUND Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. METHODS Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsification were included. Depending upon the type of OVD, patients were randomly allocated into three groups; group 1 (n = 19), Viscoat was used; group 2 (n = 19), Healon GV was used; group 3 (n = 18), Healon 5 was used. Parameters evaluated were uncorrected and best corrected visual acuity, specular microscopy, intraocular pressure and pachymetry both preoperatively and postoperatively on day 1, 1 week, 1 month and 3 months and development of any complication both intraoperative and postoperative were also noted. RESULTS The mean increase in central corneal thickness was 15.17% (group 1); 17.26% (group 2) and 16.21% (group 3) on first postoperative day and was comparable in the three groups. The density of endothelial cells decreased postoperatively (day 1) by 12.54% (group 1), 13.76% (group 2) and 13.06% (group 3) and was comparable. The mean preoperative intraocular pressure in groups 1, 2 and 3 were 13.3 +/- 2.0, 14.0 +/- 2.2 and 13.2 +/- 3.2 mmHg respectively, which changed to 16.0 +/- 4.7, 12.2 +/- 4.7 and 12.3 +/- 4.8 respectively on first postoperative day and the change in intraocular pressure was significantly higher in group 1 (1 vs 2 & 1 vs 3; p = 0.02; oneway ANOVA). CONCLUSION Viscoat, Healon GV and Healon 5 give comparable results in terms of efficacy and safety in performing phacoemulsification.
منابع مشابه
Comparative Evaluation of Efficacy and Safety of Ophthalmic Viscosurgical Devices in Phacoemulsification
Background: Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. Methods: Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsifica...
متن کاملSafety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery
PURPOSE To evaluate the safety and efficacy of DisCoVisc ophthalmic viscosurgical device (OVD, Alcon Laboratories, Inc) with respect to a comparator, Healon OVD (Advanced Medical Optics, Inc). PATIENTS AND METHODS In this prospective study, patients with cataracts were randomized to an OVD, and then received phacoemulsification and injection of an intraocular lens. After each surgery, unmaske...
متن کاملA clinical comparison between DisCoVisc and 2% hydroxypropylmethylcellulose in phacoemulsification: a fellow eye study
OBJECTIVE This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized techniqu...
متن کاملSafety and efficacy of two ocular anesthetic methods for phacoemulsification: topical anesthesia and viscoanesthesia (VisThesia).
PURPOSE VisThesia is a new ophthalmic viscosurgical device (OVD) which has 1% lidocaine combined with 1.5% sodium hyaluronate. This is a prospective evaluation of the safety and efficacy of VisThesia used in association with phacoemulsification. METHODS A total of 114 eyes were divided into two groups. Fifty-nine eyes were treated with tetracaine + oxybuprocaine topical anesthesia and DuoVisc...
متن کاملComparison of corneal endothelial cell loss during phacoemulsification using continuous anterior chamber infusion versus those using ophthalmic viscosurgical device: Randomized controlled trial
AIM We conducted this study to evaluate and compare corneal endothelial cell loss between phacoemulsification with continuous anterior chamber infusion using anterior chamber maintainer (ACM) and phacoemulsification using ophthalmic viscosurgical device (OVD). MATERIALS AND METHODS This was a prospective, randomized controlled trial. Fifty eyes of 47 patients of senile cataract undergoing pha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- BMC Ophthalmology
دوره 5 شماره
صفحات -
تاریخ انتشار 2005