Acoustic versus electronic modifications of hearing aid low-frequency output.

نویسندگان

  • R M Cox
  • G C Alexander
چکیده

The rated quality and intelligibility of speech processed by hearing aids in which the low-frequency output had been reduced by either electronic modification (low-cut tone controls) or acoustic modification (vented or open earmolds) was investigated. Fifteen subjects with high-frequency hearing loss provided data for nine commercial hearing aids and both high and low background noise levels. Results for both background noise levels indicated that for hearing aids with a low-frequency cut off at or above 750 Hz (as measured in this investigation), the use of a vented or open earmold significantly improved both quality and intelligibility even when it had essentially no effect on the hearing aid's low-frequency output. The implication of the outcome is that for an individual with essentially normal low-frequency sensitivity and a high-frequency hearing loss, an earmold incorporating an opening should be used whenever possible, even though it may not be used for the purpose of controlling low-frequency amplification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Musical Instrument Recognition in Combined Electric and Acoustic Cochlear Implant Simulations

The present study investigated listeners’ performance in a closed-set musical instrument recognition task through simulations of a cochlear implant (CI) and electric-acoustic stimulation (EAS), where the use of a CI is supplemented by a hearing aid to access low-frequency residual hearing. The recognition rates varied across the different musical instruments, with higher scores for instruments ...

متن کامل

Optimizing Hearing for Listeners with a Cochlear Implant and Contralateral Hearing Aid

Why a new prescriptive fitting formula? First, combined electric and contralateral acoustic stimulation provides substantial benefits to bimodal listeners, including better speech understanding in noise and voice pitch perception, enhanced localization abilities, and improved music perception.1-3 However, conventional hearing aid prescriptions (e.g., NAL-NL2, DSL v5) do not align acoustic and e...

متن کامل

Perception of internally generated noise in hearing amplification.

Noise generated within hearing aid amplifiers is distracting and, if the level is high enough, may interfere with speech communication. For hearing aid specification and fitting, it is useful to know the acoustic levels at which internal amplifier noise becomes audible and at which it becomes objectionable. This paper reports, for eight subjects with moderate hearing losses, the perceived level...

متن کامل

A Technical Comparison of Digital Frequency-Lowering Algorithms Available in Two Current Hearing Aids

BACKGROUND Recently two major manufacturers of hearing aids introduced two distinct frequency-lowering techniques that were designed to compensate in part for the perceptual effects of high-frequency hearing impairments. The Widex "Audibility Extender" is a linear frequency transposition scheme, whereas the Phonak "SoundRecover" scheme employs nonlinear frequency compression. Although these sch...

متن کامل

How Do Vents Affect Hearing Aid Performance?

with an occluding earmold; data above “0” suggest a gain increase (from resonance) while that below “0” suggest gain reduction with the specific vent dimension (length and diameter). The solid line shows the result of a 6 mmlong vent, while the dotted line shows that of a 22 mm-long vent. For both vent lengths, one sees more low-frequency gain reduction as the vent diameter increases. For examp...

متن کامل