Direct aneurysm sac catheterization and embolization of an enlarging internal iliac aneurysm using cone-beam CT.
نویسندگان
چکیده
Since cone-beam computed tomography (CT) has been adapted for use with a C-arm system it has brought volumetric CT capabilities in the interventional suite. Although cone-beam CT image resolution is far inferior to that generated by traditional CT scanners, the system offers the ability to place an access needle into position under tomographic guidance and use the access to immediately begin a fluoroscopic procedure without moving the patient. We describe a case of a "jailed" enlarging internal iliac artery aneurysm secondary to abdominal aortic aneurysm repair, in which direct percutaneous puncture of the internal iliac artery aneurysm sac was performed under cone-beam CT guidance.
منابع مشابه
Experience of direct percutaneous sac injection in type II endoleak using cone beam computed tomography
Cone beam CT, usually used in dental area, could easily obtain 3-dimensional images using cone beam shaped ionized radiation. Cone beam CT is very useful for direct percutaneous sac injection (DPSI) which needs very precise measurement to avoid puncture of inferior vena cava or vessel around sac or stent graft. Here we describe two cases of DPSI using cone beam CT. In case 1, a 79-year-old male...
متن کاملNovel Treatment of an Enlarging Internal Iliac Artery Aneurysm in Association with a Type 2 Endoleak via Percutaneous Embolisation of the Superior Gluteal Artery through a Posterior Approach
Internal iliac artery (IIA) aneurysms, while rare, carry a significant risk of mortality if they rupture. Endovascular intervention is now the preferred method of treatment for IIAs; however, due to technical considerations, this is not always feasible. We report a case of a patient who developed an enlarging IIA aneurysm in association with a type 2 endoleak supplied by multiple feeding arteri...
متن کاملSuccessful endovascular coiling of a ruptured internal iliac artery aneurysm: a case report
Ruptured internal iliac artery aneurysms (IIAA) are extremely rare, and the repair can be challenging. This case reports described an 83-year-old patient who presented at our Emergency Department with acute abdominal pain based on a ruptured IIAA. He refused open repair and only wanted to be treated as minimally invasive as possible. Therefore endovascular embolization of the IIAA was performed...
متن کاملDirect Puncture Embolization of a Recurrent Internal Iliac Artery Aneurysm with N-Butyl-2-Cyanoacrylate Under Flow-Control with Balloon
Background If only proximal embolization or ligation is performed for an internal iliac artery aneurysm (IIAA), transcatheter arterial embolization is sometimes difficult due to complex collateral circulation. A new method of direct percutaneous n-butyl-2-cyanoacrylate (NBCA) sac embolization (b-DNSE) under balloon arterial occlusion for re-intervention of an IIAA after proximal ligation is pre...
متن کاملEvaluation of Visibility by Metal Artifact Reduction during Stent-assisted Coil Embolization
Objective: In cases of stent-assisted coil (SAC) embolization, visualization of stents with cone-beam CT is interfered significantly by the coil mass with streak artifacts. Metal artifact reduction (MAR), which is the algorithm for contrastenhanced cone-beam CT, improves visualization of stents. We analyzed our cases of SAC embolization and report efficacy of MAR. Materials and Methods: We revi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Diagnostic and interventional radiology
دوره 21 3 شماره
صفحات -
تاریخ انتشار 2015