Schiff's Bases and Crown Ethers as Supramolecular Sensing Materials in the Construction of Potentiometric Membrane Sensors

نویسندگان

  • Farnoush Faridbod
  • Mohammad Reza Ganjali
  • Rassoul Dinarvand
  • Parviz Norouzi
  • Siavash Riahi
چکیده

Ionophore incorporated PVC membrane sensors are well-established analyticaltools routinely used for the selective and direct measurement of a wide variety of differentions in complex biological and environmental samples. Potentiometric sensors have someoutstanding advantages including simple design and operation, wide linear dynamic range,relatively fast response and rational selectivity. The vital component of such plasticizedPVC members is the ionophore involved, defining the selectivity of the electrodes' complexformation. Molecular recognition causes the formation of many different supramolecules.Different types of supramolecules, like calixarenes, cyclodextrins and podands, have beenused as a sensing material in the construction of ion selective sensors. Schiff's bases andcrown ethers, which feature prominently in supramolecular chemistry, can be used assensing materials in the construction of potentiometric ion selective electrodes. Up to now,more than 200 potentiometric membrane sensors for cations and anions based on Schiff's bases and crown ethers have been reported. In this review cation binding and anioncomplexes will be described. Liquid membrane sensors based on Schiff's bases and crownethers will then be discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Study on the Removal of Chromium(VI) Oxanions from Acid Solutions by Using Oxonium Ion-Crown Ether Complexes as Mobile Carrier Agents

Crown ethers 12-crown-4 (12C4), benzo-15-crown-5 (B15C5), 18-crown-6 (18C6), nitrobenzo-18-crown-6 (NB18C6) dibenzo-18-crown-6 (DB18C6) and dicyclohexyl-18-crown-6 (DC18C6), dissolved in dichloromethane, are able to form oxonium-ion complexes in contact with aqueous sulfuric and hydrochloric acid solutions. This ability allows the transfer of Cr(VI) oxanions from the acid media, through an ...

متن کامل

Membrane and Films Based on Novel Crown-Containing Dyes as Promising Chemosensoring Materials

This paper discusses several works on supramolecular systems such as monolayer and multilayer, polymer films of various crown-containing dyes, surface-active monomers and polymers. Design, production and investigation of the membrane nanostructures based on crown ethers is a rapidly developing field at the "junction" of materials sciences and nanotechnology. These nanostructures can serve as co...

متن کامل

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

Cyclodextrin Derivatives as Chiral Supramolecular Receptors for Enantioselective Sensing

In view of the chiral nature of many bio-molecules (and all bio-macromolecules), most of therapeutically active compounds which target these molecules need to be chiral and “good handed” to be effective. In addition to asymmetric synthetic and separation methodologies, enantioselective chemical sensors, able to distinguish between two enantiomers of the same molecule, are of relevance. In order...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008