Dynamic changes in the tear film in dry eyes.
نویسندگان
چکیده
PURPOSE To examine the dynamics of the tear film in patients with dry eye by measuring the wavefront aberrations of the anterior surface of the film. METHODS Anterior surface aberrations for a 7-mm pupil were determined in 13 patients with dry eye at 1-second time intervals, for 15 seconds after a blink. The aberrations were calculated from the elevations provided by corneal topography. All data were decomposed using Zernike polynomials. Total, spherical, and comalike aberrations terms were studied separately. Results were compared with those in normal eyes. Outcome measures included comparison with clinical tear breakup time measurements. RESULTS The total root mean square (RMS) wavefront aberration in patients with dry eye passed through in a minimum of 2.9 +/- 0.4 seconds after a blink in comparison to the minimum at 6.1 +/- 0.5 seconds in normal patients. In both groups, the minimum in total aberration appeared to be associated with similar changes in comalike aberrations, rather than in spherical aberrations, which increased monotonically with time. The time at which minimum RMS aberration occurred correlated reasonably well with the measured tear breakup times. CONCLUSIONS Measurements of the dynamic changes in the optical aberrations introduced by the anterior tear film surface give valuable insights into tear film changes and may provide a convenient objective method for the diagnosis of dry eye.
منابع مشابه
Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.
PURPOSE To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument. SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Evaluation of diagnostic test or technology. METHODS Dynamic recording of double-pass retinal images during unforced tear-film break...
متن کاملThe importance of the precorneal tear film for the quality of optical imaging.
The optical function of the eye critically depends on the presence of an intact precorneal tear film. Abnormalities of the tear film such as those occurring in the dry eye syndrome or in otherwise irritated eyes may interfere with vision. In 30 patients with dry eyes artificial tears were found to produce statistically significant improvement of vision (p less than 0.001) while no significant c...
متن کاملA novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.
PURPOSE To report a novel method for pachymetry mapping of human precorneal tear film using Pentacam. METHODS Precorneal tear film is routinely undetected by Pentacam but could be well visualized with the aid of fluorescein. Twenty patients with dry eye and 20 age-matched control subjects with normal eyes were enrolled in this prospective study. The right eye of each subject was scanned once ...
متن کاملEffect of Topical Antiglaucoma Drugs on Tear Film in Human Eyes
Objective(s): Evaluate the effect of topical antiglaucoma drugs on tear film and determine the time taken to develop symptoms and or signs of dry eye in diagnosed open angle glaucoma patients by Schirmer's test I, Schirmer's test II, Tear film break up time. Method(s): This prospective study was carried out in 60 patients attending Ophthalmology outdoor with newly diagnosed patients of primary ...
متن کاملRole of the tear film in the optical quality of the human eye.
This paper reviews recent studies of the role of the tear film in the optical quality of the eye. Recent investigations focus on the dynamics of the tear film after a blink and its important role in the optical quality of the eye. The results in this review were used in an attempt to understand the optical and visual impact of tear-film breakup in normal eyes and dry eyes. It was noted that pat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 46 5 شماره
صفحات -
تاریخ انتشار 2005