In Situ Rapid Evaluation of Indoor Bioaerosols Using an ATP Bioluminescence Assay

نویسندگان

  • Chien-Jung Lin
  • Yi-Tun Wang
  • Kuo-Jung Hsien
  • Ying I. Tsai
  • Pei-Yi Kung
  • Jih-Ming Chyan
چکیده

An adenosine-5’-triphosphate (ATP) bioluminescence method was developed for detecting microbial activity in indoor air. This method was compared with the traditional method of collecting, culturing and counting CFUs. A comparison of the results showed that ATP bioluminescence, expressed as RLUs, was moderately correlated with the entire set of CFU counts (r = 0.607), and that the correlation improved to r = 0.963 (p value < 0.001) when CFU outliers were removed from the calculations. The ATP bioluminescence method was applied at four different sites; a hospital Chinese medicine diagnostic room, a library, a government office, and a railway station lobby. The results showed that microbial activity was far higher in the railway station lobby than at the other three sites, and this is believed to be due to the higher volume and density of people in this space. At all four sites, higher microbial activity was linked to indoor plants, garbage cans, shoe racks, and furnished waiting areas. PCA of the data showed that microbial activity in the Chinese medicine diagnostic room was closely related to room temperature and humidity, and hence lowering the latter can reduce the potential for microbial activity at this site. At all four sites, no correlation was found between microbial activity and airborne pollutants. The ATP bioluminescence method was applied for the rapid evaluation of room disinfection using chloride dioxide, and results showed that twenty minutes after spraying with 100 ppm ClO2, microbial activity was reduced to 38.7% of its original level. ATP bioluminescence is simpler, easier to operate, and more cost-effective than the conventional microbial culture method of evaluating microbial load. The results obtained in this research confirm that the proposed ATP bioluminescence technique is capable of instantaneously detecting microbial activity in an indoor environment. Moreover, this approach can be used for on-line evaluation of room disinfection efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler

A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min) of indoor bioaerosol concentrations with ATP bioluminescence assay using a bioaerosol sampler. For...

متن کامل

An Adenosine Triphosphate Bioluminescence Method for Evaluating the Microbial Contamination of the Salad-Preparing Tables and Salad-Serving Dishes in Restaurants of Mashhad City, Iran

Introduction: Consumption of vegetable products is increasing commonly in the world because they are recognized as an important source of nutrients, vitamins, and fiber for humans. Salads are among the most widely used foods that are also known as the most contaminated foods in restaurants. This study was conducted to determine the microbial contamination of salad-preparing tables and salad-ser...

متن کامل

Rapid Diagnosis of Bacteriuria by Measuring Bacterial Adenosine Triphosphate Using a Bioluminescence Assay

A rapid method for quantifying bacteriuria was evaluated in 114 clinical specimens using a bacterial adenosine triphosphate (ATP) assay. The procedure allows for removal and destruction of non-bacterial ATP and subsequent analysis of bacteria ATP by firefly (Photinus pyralis) luciferin -luciferase bioluminescence and requires 30 minutes as a whole. The correlation coefficient between the number...

متن کامل

Measurement of Michaelis Constants for ATP and Mg2+ in Bioluminescence Reaction of Luciferase by a Home-Made Luminometer

Effects of ATP and Mg2+ concentrations on bioluminescence reaction of luciferase (Photinus pyralis) were investigated by home-made luminometer. The Michaelis constants of the enzyme for ATP and Mg2+ obtained from the Lineweaver-Burk graph, were 61.9 mM ±3.3 mM and 251.6mM ± 39.0mM...

متن کامل

Use of a newly developed rapid microbial ATP bioluminescence assay to detect microbial contamination on poultry carcasses.

A newly developed rapid microbial ATP bioluminescence test (R-mATP) was shown to be an adequate means to assay the microbial load of poultry carcasses. This assay utilizes differential extraction and filtration to separate somatic from microbial ATP in a very rapid timeframe. The assay requires approximately 5 min to complete; approximately 3.5 min to sample and 90 s analytical time. Correlatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013