New technique for implantation of the inflow canula of Berlin Heart INCOR system.

نویسندگان

  • Alexander Tschirkov
  • Dimitar Nikolov
  • Vassil Papantchev
چکیده

Berlin Heart INCOR system is a left ventricle assist device (LVAD), which generates a laminar blood flow. Its inflow canula is implanted in the heart apex, while its outflow canula-in the ascending aorta. In the present work a new alternative technique for implantation of the device's inflow canula is reported. The suggested technique is quicker and easier than the conventional one. It saves time and gives excellent results. After the implantation no unusual events like thrombosis, anastomosis malfunction, etc., are observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tentacles: a novel device for exposing the heart for the insertion of left apical assist device cannulae.

BACKGROUND The implantation of ventricular assist devices is a well-established procedure for the treatment of imminent heart failure. The exact positioning of the left ventricular apical inflow cannula is crucial, because inflow restrictions might occur when the cannula is placed too close to the interventricular septum or a papillary muscle. We report a novel technique using the Tentacles 3-p...

متن کامل

Integrating the Population Perspective into Health System Performance Assessment (IPHA): Study Protocol for a Cross-Sectional Study in Germany Linking Survey and Claims Data of Statutorily and Privately Insured

Background Health system performance assessment (HSPA) is a major tool for evidence-based governance in health systems and patient/population-orientation is increasingly considered as an important aspect. The IPHA study aims (1) to undertake a comprehensive performance assessment of the German health system from a population perspec...

متن کامل

Exploring Health System Responsiveness in Ambulatory Care and Disease Management and its Relation to Other Dimensions of Health System Performance (RAC) – Study Design and Methodology

Background The responsiveness of a health system is considered to be an intrinsic goal of  health systems and an essential aspect in performance assessment. Numerous studies have analysed health system responsiveness and related concepts, especially across different countries and health systems. However, fewer studies have applied the concept for the evaluation of specific healthcare delivery s...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 2006