Bubble number saturation curve and asymptotics of hypobaric and hyperbaric exposures.

نویسنده

  • B R Wienke
چکیده

Within bubble number limits of the varying permeability and reduced gradient bubble models, it is shown that a linear form of the saturation curve for hyperbaric exposures and a nearly constant decompression ratio for hypobaric exposures are simultaneously recovered from the phase volume constraint. Both limits are maintained within a single bubble number saturation curve. A bubble term, varying exponentially with inverse pressure, provides closure. Two constants describe the saturation curve, both linked to seed numbers. Limits of other decompression models are also discussed and contrasted for completeness. It is suggested that the bubble number saturation curve thus provides a consistent link between hypobaric and hyperbaric data, a link not established by earlier decompression models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decompression to altitude: assumptions, experimental evidence, and future directions.

Although differences exist, hypobaric and hyperbaric exposures share common physiological, biochemical, and clinical features, and their comparison may provide further insight into the mechanisms of decompression stress. Although altitude decompression illness (DCI) has been experienced by high-altitude Air Force pilots and is common in ground-based experiments simulating decompression profiles...

متن کامل

The Physiology and Pathophysiology of the Hyperbaric and Diving Environments Decompression to altitude: assumptions, experimental evidence, and future directions

Foster PP, Butler BD. Decompression to altitude: assumptions, experimental evidence, and future directions. J Appl Physiol 106: 678–690, 2009. First published December 12, 2008; doi:10.1152/japplphysiol.91099.2008.—Although differences exist, hypobaric and hyperbaric exposures share common physiological, biochemical, and clinical features, and their comparison may provide further insight into t...

متن کامل

Physiological equivalence of normobaric and hypobaric exposures of humans to 25,000 feet (7620 m).

INTRODUCTION Skepticism exists about whether normobaric and hypobaric hypoxic exposures are equivalent. We have evaluated if physiological differences between the two environments would translate into actual differences in hypoxia symptoms. METHODS We exposed 20 subjects to 5-min 25,000-ft (7620-m) equivalent environments in an altitude chami ber and then in a ground-level portable reduced-ox...

متن کامل

Effect of a short-acting NO donor on bubble formation from a saturation dive in pigs.

It has previously been reported that a nitric oxide (NO) donor reduces bubble formation from an air dive and that blocking NO production increases bubble formation. The present study was initiated to see whether a short-acting NO donor (glycerol trinitrate, 5 mg/ml; Nycomed Pharma) given immediately before start of decompression would affect the amount of vascular bubbles during and after decom...

متن کامل

In-vitro performance of the Enlite Sensor in various glucose concentrations during hypobaric and hyperbaric conditions.

BACKGROUND There is a need for reliable methods of glucose measurement in different environmental conditions. The objective of this in vitro study was to evaluate the performance of the Enlite® Sensor when connected to either the iPro™ Continuous Glucose Monitor recording device or the Guardian® REAL-Time transmitting device, in hypobaric and hyperbaric conditions. METHODS Sixteen sensors con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of bio-medical computing

دوره 29 3-4  شماره 

صفحات  -

تاریخ انتشار 1991