Catheter for Percutaneous Transluminal Angioplasty Validation of Imaging, Analysis of Recoil, and Identification of Plaque Fracture
نویسنده
چکیده
Background. We investigated the hypothesis that an ultrasound transducer positioned within an angioplasty balloon could be used to perform quantitative assessment of arterial dimensions before and after percutaneous transluminal angioplasty (PTA) and to identify certain mechanical alterations consequent to PTA, including vascular wall recoil and the initiation of plaque fractures. Methods and Results. A combination balloon-ultrasound imaging catheter (BUIC) that houses a 20-MHz ultrasound transducer within and halfway between the proximal and distal ends of an angioplasty balloon was used to perform PTA in 10 patients with peripheral vascular disease. Each PTA site was also evaluated before and after PTA by standard (nonballoon) intravascular ultrasound (IVUS) technique. In eight patients in whom satisfactory images were recorded with the BUIC before PTA, luminal cross-sectional area (XSA) of stenotic sites (0.10±0.01 cm2) did not differ significantly from measurements of XSA by IVUS (0.09±0.01 cm2, p=NS). Likewise, minimum luminal diameter (Dmin) measured by BUIC (0.34+±0.02 cm) was similar to that measured by IVUS (0.33±0.01 cm, p=NS). In nine patients in whom satisfactory images were recorded with the BUIC after PTA, XSA measured by BUIC (0.29±0.03 cm2) did not differ significantly from XSA measured by IVUS (0.30±0.03 cm2, p=NS). Dmin measured by BUIC after PTA (0.57±0.02 cm) was also similar to D.,. measured by IVUS (0.57+±0.03 cm,p=NS). After PTA, XSA and Dmin measured immediately after deflation were significantly less than balloon XSA and diameter at full inflation, indicating significant elastic recoil of the dilated site. For the nine patients in whom post-PTA images were satisfactory for quantitative analysis, including four patients in whom recoil was 39%o, 46%, 50%, and 61%, percent recoil measured 28.6+7.2%. Finally, plaque fractures were identified on-line in six of 10 patients (60%); in each case, initiation of plaque fracture was observed at inflation pressures of 2 atm or less. Conclsions. The results of this preliminary human investigation indicate that an ultrasound transducer positioned within an angioplasty balloon can be used to perform quantitative and qualitative analyses of lumen-plaque-wall alterations immediately preceding, during, and immediately after PTA in patients with peripheral vascular disease. (Circulation 1991;84:739-754)
منابع مشابه
Combination balloon-ultrasound imaging catheter for percutaneous transluminal angioplasty. Validation of imaging, analysis of recoil, and identification of plaque fracture.
BACKGROUND We investigated the hypothesis that an ultrasound transducer positioned within an angioplasty balloon could be used to perform quantitative assessment of arterial dimensions before and after percutaneous transluminal angioplasty (PTA) and to identify certain mechanical alterations consequent to PTA, including vascular wall recoil and the initiation of plaque fractures. METHODS AND ...
متن کاملThe value of myocardial perfusion imaging with Tc-99m MIBI for the prediction of perfusion improvement after percutaneous transluminal coronary angioplasty
Introduction: Percutaneous transluminal coronary angioplasty (PTCA) is an effective method for revascularizing of stenotic coronary vessels. Lack of response to this treatment, either in symptomatic or asymptomatic patients, is usually due to incomplete revascularization, restenosis, and/or irreversibility of myocardial perfusion. Introduction of a noninvasive metho...
متن کاملAssessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)
Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...
متن کاملValidation of an automated technique for determining the mechanical characteristics of coronary arteries during balloon angioplasty: laboratory assessment with necropsy segments.
OBJECTIVES To develop a technique for automatic inflation of a percutaneous transluminal coronary angioplasty (PTCA) balloon, with continuous measurement of the balloon pressure and volume; to validate the technique for determining the mechanical characteristics of coronary arteries. METHODS During necropsy examination of the hearts of nine patients, 17 coronary artery samples were obtained f...
متن کاملPathological findings after percutaneous transluminal coronary angioplasty.
Ten serial pathological cross sections at 1 mm intervals of both the left anterior descending artery at the site of a percutaneous transluminal coronary angioplasty and of the circumflex artery in the untreated stenotic area were studied at necropsy in a patient who died immediately after the procedure. The extent of calcification and atheroma were similar in both branches. Intimal or medial sp...
متن کامل