Commissioning and evaluation of a new commercial small rodent x-ray irradiator
نویسندگان
چکیده
An appropriate radiation source is essential in studies of tissue response in animal models. This paper reports on the evaluation and commissioning of a new irradiator suitable for studies using small animals or cell culture. The Faxitron is a 160-kVp x-ray machine that was adapted from an x-ray imaging unit through modifications to facilitate experimental irradiation. The x-ray unit is housed in a shielded cabinet, and is configured to allow multiple irradiation positions and a range of field sizes and dose rates. Use of this machine for animal irradiation requires characterisation of relevant dosimetry, and development of methodology for secondary beam collimation and animal immobilisation. In addition, due to the limitation of the irradiator, the optimal selection of three characteristics of the x-ray beam is important. These three characteristics, namely, the dose rate, the beam uniformity, and the field size are inter-dependent and the selection of a combination of these parameters is often a compromise and is dependent on the application. Two different types of experiments are selected to illustrate the applicability of the Faxitron. The Faxitron could be useful for experimental animal irradiation if the experimental design is carried out carefully to ensure that accurate and uniform radiation is delivered.
منابع مشابه
Evaluation of a systemic change of Superficial X-ray tube characteristics
Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...
متن کاملBiological X-ray irradiator characterization for use with small animals and cells
This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the p...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملEvaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff
Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), a...
متن کاملEvaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013
Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...
متن کامل