Analysis of T1 weighted Spiral Projection Imaging

نویسندگان

  • R. K. Robison
  • J. G. Pipe
چکیده

OBJECTIVE: Spiral Projection Imaging (SPI) is a versatile, fast 3D data acquisition. Data are sampled on 2D spiral planes that are rotated to fill a sphere in k-space (figure 1). The spiral basis of SPI provides flow insensitivity. Furthermore, it has been shown that SPI allows for six degrees of motion correction similar to that used in PROPELLER. SPI requires far fewer excitations than a line-by-line 3D Cartesian acquisition. This provides flexibility in the TR and thus a potential advantage in scan time, resolution, or SNR. However, the spiral and PR bases of SPI make it susceptible to off-resonance blurring and gradient inconsistencies. The goal of this study was to compare 3D spoiled gradient echo T1-weighted SPI images with similar Cartesian images to analyze the artifacts seen in SPI. While the focus here is on SPI, similar artifacts may be observed in other imaging trajectories. METHODS: Data were acquired with the SPI trajectory on a GE 3T Signa Excite 3.0T (9.8ms TR, 20° flip, 410 planes, 90 interleaves, 6’10” scan time). A short ADC time (~2.4 ms) was used to minimize off-resonance blurring effects. Ultimately, SPI should use fewer interleaves, yielding improved resolution or reduced scan time but also introducing greater off-resonance blurring making off-resonance correction vital. Data were also obtained for a Cartesian acquisition (6.5ms TR, 16° flip, 240 frequency encode, 240x240 phase encodes, 6’13” scan time). RESULTS: The figures show inferior image quality in SPI compared to the Cartesian scan. Severe distortions occur in some regions of the SPI images due to fat off-resonance that can be readily addressed with fat saturation. Subtle distortions seen within the brain tissue are more difficult to resolve. The measured SNR of the SPI data in figure 2 is 49% of the Cartesian data, but should theoretically be about 85% for the parameters specified above. This discrepancy may be explained in part by artifacts seen in the SPI images, as the measured SNR of the SPI phantom data is about 93% that of the Cartesian phantom data. Simulated SPI data demonstrate an imperceptible loss in image quality. However, when kspace coordinates derived from slightly delayed or misaligned gradient waveforms are used to reconstruct the simulated data, artifacts similar to those seen in the SPI phantom data are observed. Large improvements in SPI image quality were observed when a 4μs gradient group delay was measured and corrected. It is thus assumed that much of the remaining degradation seen in the acquired SPI data results from k-space coordinate inconsistencies due to gradient delays and other system imperfections. Methods exist for measuring actual k-space coordinates and should be used to further characterize these effects. REFERENCES: 1)Proc. ISMRM 2008, Abstract 1470. 2)Proc. ISMRM 2008, Abstract 1469. 3)Mag. Res. Med., 42(5); 963-9. 4)Mag. Res. Med., 34(3); 446-56. 5)Mag. Res. Imaging, 15(5); 567-78. 6)Mag. Res. Med., 39(4); 581-7. 7)Mag. Res. Med., 38(3); 492-6. Fig. 1 Spiral planes are used to fill a sphere in k-space.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

I-41: Imaging Strategy for Diagnosis of Adnexal Masses Including US,CT Scan and MRI

Adnexal masses are spectrum of diseases from benign non neoplastic and neoplastic masses to malignant neoplasms. Endovaginal ultrasonography (US) is the fisrt and invaluable modality for assessment of adnexal masses because it is available and has a high negative predictive value. Important morphologic features are solid (vascularized) tissue, vascular and thick septations, and papillary projec...

متن کامل

The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence

  Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...

متن کامل

A Spiral Spin-Echo MR Imaging Technique for Improved Flow Artifact Suppression in T1-Weighted Postcontrast Brain Imaging: A Comparison with Cartesian Turbo Spin-Echo.

BACKGROUND AND PURPOSE A challenge with the T1-weighted postcontrast Cartesian spin-echo and turbo spin-echo brain MR imaging is the presence of flow artifacts. Our aim was to develop a rapid 2D spiral spin-echo sequence for T1-weighted MR imaging with minimal flow artifacts and to compare it with a conventional Cartesian 2D turbo spin-echo sequence. MATERIALS AND METHODS T1-weighted brain im...

متن کامل

Brain segmentation performance using T1-weighted images versus T1 maps

The recent driven equilibrium single-pulse observation of T1 (DESPOT1) approach permits real-time clinical acquisition of large-volume and high-isotropic-resolution T1 mapping of MR tissue parameters with improved uniformity. It is assumed that the quantitative nature of maps will facilitate clinical applications such as disease diagnosis and comparison across subjects. However, there is not ye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008