"Pierce and inhale" design in capsule based dry powder inhalers: Effect of capsule piercing and motion on aerodynamic performance of drugs.

نویسندگان

  • Francesco Martinelli
  • Anna Giulia Balducci
  • Alessandra Rossi
  • Fabio Sonvico
  • Paolo Colombo
  • Francesca Buttini
چکیده

In this work three capsule-based dry powder inhalers, available for generics product development, were compared. Two technologically different dry powder formulations were used in order to relate the capsule piercing position and motion in the device to their aerodynamic performance. A "pierce and inhale" design, in which the capsules pierced with RS01, HandiHaler or Turbospin devices were aerosolized in the same device or transferred and aerosolized with another device, was constructed and carried out. The results obtained showed that two dry powder formulations, i.e., a drug/lactose blend or a carrier-free powder, aerosolized using capsule based inhalers, performed differently. The aerosolization of drug carrier mixture in terms of drug dispersion and emitted dose, was more sensible to the piercing and device combination than the carrier free powder. The motion of the capsule during the aerosolization boosted the powder emission, whereas the powder disaggregation was more influenced by the airflow pattern around the capsule and inside the inhaler turbulence chamber.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delivery characteristics of a low-resistance dry-powder inhaler used to deliver the long-acting muscarinic antagonist glycopyrronium*

OBJECTIVES The long-acting muscarinic antagonist (LAMA) glycopyrronium (NVA237) has recently been approved as a once-daily treatment for COPD. The objectives of this study were to determine the dose delivery characteristics of glycopyrronium and compare them with those of the LAMA tiotropium, both delivered by their respective capsule-based dry-powder inhalers (DPIs). RESEARCH DESIGN AND METH...

متن کامل

Impact of capsule selection on formulation stability in dry powder inhalers (DPIs)

The delivery of inhalation-based formulations is achieved by devices that fall into three segments: nebulizers, metered dose inhalers (MDIs), and dry powder inhalers (DPIs).2 There is much discussion about which device is most appropriate, though that discussion is well beyond the scope of this article. It is of note however, that MDIs and DPIs have been shown to function equally well when pati...

متن کامل

Pharmaceutical equivalence of the combination formulation of budesonide and formoterol in a single capsule with a dry powder inhaler.

OBJECTIVE To evaluate the pharmaceutical equivalence of a test formulation (fixed-dose combination of budesonide and formoterol fumarate in a single capsule dispensed in an Aerocaps® inhaler) in relation to a reference formulation (budesonide and formoterol fumarate in two separate capsules dispensed in an Aerolizer® inhaler). METHODS This was an in vitro study in which we performed the ident...

متن کامل

Delivery characteristics and patients’ handling of two single-dose dry-powder inhalers used in COPD

For optimal efficacy, an inhaler should deliver doses consistently and be easy for patients to use with minimal instruction. The delivery characteristics, patients' correct use, and preference of two single-dose dry powder inhalers (Breezhaler and HandiHaler) were evaluated in two complementary studies. The first study examined aerodynamic particle size distribution, using inhalation profiles o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of pharmaceutics

دوره 487 1-2  شماره 

صفحات  -

تاریخ انتشار 2015