Development of the Residential Load Factor Method for Heating and Cooling Load Calculations
نویسندگان
چکیده
The recent ASHRAE project, “Updating the ASHRAE/ ACCA Residential Heating and Cooling Load Calculation Procedures and Data” (RP-1199), developed two new residential loads calculation procedures: residential heat balance (RHB), a detailed heat balance method that requires computer implementation, and residential load factor (RLF), a simplified procedure that is hand tractable and suitable for spreadsheet implementation. This paper describes RLF and its development. The form of RLF resembles prior methods. However, the sensible cooling load procedure was derived using linear regression to find relationships between design conditions, building characteristics, and peak cooling load predicted by RHB. This eliminated the need for semi-empirical adjustments, such as averaging, that have been used in the development of other methods. Results comparing RLF to RHB are presented. The RLF heating load calculation is also described; it uses the traditional UA∆T formulation except for improvements to procedures for infiltration leakage rate and ground (slab and basement) losses.
منابع مشابه
An Optimized Design of a Single Effect Absorption Solar Chiller for an Energy Consuming Optimized Designed Residential Building
Traditional fossil fuels lead to environmental problems and are also depleting. A significant portion of global energy consumption is due to building’s air conditioning. Nowadays there is a great attention toward renewable and sustainable energy sources to support the buildings energy requirements. In this study, a solar cooling machine was designed for a three-floor residential building under ...
متن کاملComparative study between dynamic transient and degree-hours methods to estimate heating and cooling loads of building’s wall
In this paper, dynamic transient method and conventional degree-hours method (static) have been compared to estimate heating and cooling loads of building’s wall. All main wall surfaces of various orientations, i.e.South, West, East, North, and horizontal are considered in the climate of Tehran, Iran. In this study, a conventional wall structure, which is comprisedconcrete as main wall material...
متن کاملApplication of Phase Change Material (PCM) for Cooling Load Reduction in Lightweight and Heavyweight Buildings: Case Study of a High Cooling Load Region of Iran
The application of phase change material (PCM) for energy conservation purposes in the residential buildings was investigated in the present study. Two types of building in terms of materials as the lightweight building (LWB) and heavyweight building (HWB) located in a high cooling load demanding region of Iran were considered for the study. Different types of PCM from organic and inorganic cat...
متن کاملSoftware Development for Cooling Load Estimation by CLTD Method
Traditionally, load estimating for air conditioning systems is done either by manual calculation or judgmental estimation based on experience of the air conditioning practitioner. While manual calculation is laborious, estimate based on judgment is liable to error due to gigantic, complex and dynamic nature of present day architectural designs. Load estimating through computer automation is lik...
متن کاملResidential Load Manageability Factor Analyses by Load Sensitivity Affected by Temperature
Load side management is the basic and significant principle to keeping the balance between generation side and consumption side of electrical power energy. Load side management on typical medium voltage feeder is the power energy consumption control of connected loads with variation of essential parameters that loads do reaction to their variation. Knowing amount of load's reaction to each para...
متن کامل