Is helical tomotherapy-based intensity-modulated radiotherapy feasible and effective in bilateral synchronous breast cancer? A two-center experience.

نویسندگان

  • Kemal Ekici
  • Tumay Gokce
  • Ilker Karadogan
  • Aysun Fatma Eraslan
  • Cimen Akcay
  • Oztun Temelli
  • Eda Kaya Pepele
  • Funda Durmus Manalp
  • Caglar Keles
  • Arpaslan Mayadagli
چکیده

PURPOSE This study describes the early clinical results and dosimetric parameters of intensity-modulated radiation therapy (IMRT) using a tomotherapy device in patients with primary bilateral synchronous breast cancer (PSBBC). METHODS Fourteen patients with bilateral breast cancer were treated with tomotherapy between January 2011 and October 2014. The treatment planning objectives were to cover 95% of the planning target volume using a 95% isodose, with a minimum dose of 90% and a maximum dose of 107%. The organs at risk (OAR), such as the lungs, heart, esophagus and spinal cord, were contoured. Acute toxicity was recorded during and after radiation therapy. RESULTS The advantages included better treatment conformity with lower dosages to minimize the risk to susceptible organs, such as the lungs, heart and spinal cord. There was improved coverage of the planning target volume, including the regional nodes, without any field junction problems. The median homogeneity index was 0.13 and the median conformity index 1.32. The median V20, V15, V10 and V5 for the total lungs were 18.5, 23.3, 24.2 and 60%, respectively. Skin acute toxicity was grade 1 in 72% and grade 2 in 14% of the patients. Esophageal acute toxicity was grade 1 in 43% of the patients. CONCLUSION Tomotherapy delivers treatment that is well-tolerated, with high homogeneity and coverage indexes and the capability to reduce the irradiation dose received by the lungs and heart in PSBBC patients. This technique is therefore feasible and safe for the treatment of bilateral breast cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Bjrd14612 1..15

Objective: Synchronous malignancy in both breasts is a rare incidence. The present study aims at dosimetric comparison of conventional bitangential radiotherapy (RT) technique with conventional [field-in-field (FIF)] and rotational [Helical TomoTherapy® and TomoDirectTM (TD); Accuray Inc., Sunnyvale, CA] intensity-modulated RT for patients with synchronous bilateral breast cancer (SBBC). Method...

متن کامل

Helical tomotherapy provides efficacy similar to that of intensity-modulated radiation therapy with dosimetric benefits for endometrial carcinoma

BACKGROUND The purpose of this study was to compare the efficacy of intensity-modulated radiotherapy (IMRT) and helical tomotherapy for endometrial cancer. METHODS Between November 1, 2006 and November 31, 2010, 31 patients with histologically confirmed endometrial cancer were enrolled. All enrolled patients received total abdominal hysterectomy and bilateral salpingo-oophorectomy with adjuva...

متن کامل

Early experience of tomotherapy-based intensity-modulated radiotherapy for breast cancer treatment.

AIMS New technology - specifically intensity-modulated radiotherapy (IMRT) - is now being applied to breast radiotherapy and a recent dosimetric analysis confirmed the advantages of IMRT over 'wedge-only' plans. Such application to everyday practice raises new issues and here we present the early experience of IMRT-based breast irradiation in a single centre. MATERIALS AND METHODS We present ...

متن کامل

Low-Dose-Area-Constrained Helical TomoTherapy-Based Whole Breast Radiotherapy and Dosimetric Comparison with Tangential Field-in-Field IMRT

BACKGROUND AND PURPOSE To present a novel helical TomoTherapy-based method for whole breast radiotherapy that has better dosimetry and also has acceptable low-dose regions for lungs, heart, and contralateral breast compared with tangential field-in-field IMRT (FIF-IMRT). MATERIAL AND METHODS Ten patients with left-side breast cancer were planned with low-dose-area-constrained helical TomoTher...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of B.U.ON. : official journal of the Balkan Union of Oncology

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2016