Durability of continuous-flow left ventricular assist devices: a systematic review.
نویسندگان
چکیده
BACKGROUND Left ventricular assist devices (LVADs) are becoming an increasingly viable alternative therapy for heart failure, either as a bridge to heart transplantation (BTT) or destination therapy (DT). The latter has become increasingly popular in recent years, in the face of a donor organ shortage and a rise in elderly patients ineligible for heart transplants. For these patients in particular, device durability is a key contributor to survival, morbidity, and quality of life. This systematic review aimed to assess the long-term durability of current continuous-flow LVADs. METHODS Six electronic databases were searched from their dates of inception to August 2014 for original studies reporting on patients receiving continuous-flow LVADs. LVAD failure was defined as device malfunction necessitating exchange or explantation, or causing patient mortality. Pooled averages were calculated for outcomes and rates of device failure were reconstructed from digitized graph curves using the software, WebPlotDigitizer v3.3. RESULTS Twelve retrospective observational studies with a total of 5,471 patients were included for analysis. The mean duration of LVAD support was 504.7 (range, 303-568) days, and the overall weighted incidence of device failure was 3.9% (range, 1-11.3%). On average, pump thrombosis was the most common cause of device failure (50.5%), followed by lead or cable damage (21.7%), mechanical pump failure (11.6%), device-related infection (11.1%), and surgical complications from implantation (2.5%). Long-term device failure rates at 2-, 6-, 12-, 18- and 24-months post-implantation were 0.5%, 1.8%, 2.9%, 4.5% and 6.5%, respectively. CONCLUSIONS With the expected rise in LVAD usage for end-stage heart failure, particularly as a DT, the steady minority of patients experiencing device failure is likely to increase. Further investigation is required into the incidence and mechanism of major causes of failure, as well as design improvements that may address these complications. There is currently a lack of guidelines and large randomized studies reporting on the etiology and outcomes of LVAD failure.
منابع مشابه
Why pulsatility still matters: a review of current knowledge
Continuous-flow left ventricular assist devices (LVAD) have become standard therapy option for patients with advanced heart failure. They offer several advantages over previously used pulsatile-flow LVADs, including improved durability, less surgical trauma, higher energy efficiency, and lower thrombogenicity. These benefits translate into better survival, lower frequency of adverse events, imp...
متن کاملComparison of continuous-flow and pulsatile-flow left ventricular assist devices: is there an advantage to pulsatility?
BACKGROUND Continuous-flow left ventricular assist devices (CFVAD) are currently the most widely used type of mechanical circulatory support as bridge-to-transplant and destination therapy for end-stage congestive heart failure (HF). Compared to the first generation pulsatile-flow left ventricular assist devices (PFVADs), CFVADs have demonstrated improved reliability and durability. However, CF...
متن کاملClinical outcomes after continuous-flow left ventricular assist device: a systematic review.
BACKGROUND Conveying the complex trade-offs of continuous-flow left ventricular assist devices is challenging and made more difficult by absence of an evidence summary for the full range of possible outcomes. We aimed to summarize the current evidence on outcomes of continuous-flow left ventricular assist devices. METHODS AND RESULTS PubMed and Cochrane Library were searched from January 2007...
متن کاملFactors influencing the rate of flow through continuous-flow left ventricular assist devices at rest and with exercise.
T he heart failure (HF) community has witnessed a rapid evolution in mechanical circulatory support over the past decade. Following publication of the pivotal HeartMate II trials, continuous-flow left ventricular assist devices (cfLVADs) with an axial rotor (e.g., HeartMate II) quickly replaced the first-generation, pulsatile devices as both a bridge to transplant and as destination therapy for...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of cardiothoracic surgery
دوره 3 6 شماره
صفحات -
تاریخ انتشار 2014