Pharmacochemical profile of iopromide.

نویسندگان

  • W Muetzel
  • U Speck
چکیده

Iopromide (Schering, Berlin) is a new nonionic, monomeric contrast medium containing three different substituents on the triiodinated benzene ring. Iopromide exhibits low osmolality and viscosity in aqueous solutions of high concentrations. It has been shown to have a remarkably low intravenous toxicity in mice and rats. Neural tolerance was found to be equal to or better than that of metrizamide when injected in rats intracisternally and intracerebrally, respectively. The effects of iopromide after selective peripheral and cerebral arterial injections in rats were demonstrated to be very moderate at high dosages. The interaction of iopromide with proteins and membranes was found to be considerably low due to its hydrophilicity. Excretion of iopromide is fast and predominantly by the renal route. On the basis of the preclinical profile iopromide is a very promising contrast agent, being most suitable for all angiographic indications, including digital subtraction angiography, urography, and computed tomography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fixed Drug Eruption due to Iopromide (Ultravist®)

A 69-year-old male presented with several painful erythematous patches on both palms and trunk several days after receiving iopromide (Ultravist®, Shering, Berlin, Germany). A fixed drug eruption (FDE) due to iopromide was suspected clinically. However, at that time, the patch test with iopromide at the lesion site gave negative results. Three years later, the patient was mistakenly administere...

متن کامل

The Choice of Contrast Media in the Cardiac Catheterisation Laboratory

Contrast media (CM) in cardiology is used in vessel visualisation, stenosis identification, localisation and identification of vessel ramifications and cardiovascular malformations. The identification of a CM that has the optimum visual properties and a safe profile was investigated in this study, along with other significant parameters. Quantitative assessment in choosing appropriate CM was in...

متن کامل

Is contrast-related vasodilatation after intra-coronary iodixanol and iopromide in vivo endothelium-dependent?

AIMS Goals of the study were the assessment of the correlation between flow-dependent and contrast-related vasodilatation, comparison of iodixanol to iopromide and evaluation of the impact of plaque on vasodilatation in coronary arteries. METHODS AND RESULTS A controlled randomized paired cross-over comparison between iodixanol (320mgI.ml(-1)) and iopromide (300mgI.ml(-1)) was performed in 10...

متن کامل

Viscosity of contrast media perturbs renal hemodynamics.

Contrast-induced nephropathy is a common cause of acute renal failure, and the mechanisms underlying this injury are not completely understood. We sought to determine how physicochemical properties of contrast media may contribute to kidney damage in rats. We administered contrast media of equivalent iodine concentrations but differing physiocochemical properties: the high-osmolality iopromide ...

متن کامل

Determination of iopromide in environmental waters by ion chromatography - ICP - MS

The determination of iopromide in environmental waters has been accomplished using an Agilent 7700x ICP-MS coupled to an Agilent 1260 LC. The use of High Matrix Introduction (HMI) technology allows for prolonged operation with a sodium hydroxide (NaOH) eluent, and the Octopole Reaction System (ORS3) in helium gas mode reduces polyatomic interferences on iodine (m/z 127). Determination of ioprom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 4 3  شماره 

صفحات  -

تاریخ انتشار 1983