Evaluation of the Effect of Axial Wall Modification and Coping Design on the Retention of Cement-retained Implant-supported Crowns

نویسندگان

  • Reza Derafshi
  • Ahmad Hasan Ahangari
  • Kianoosh Torabi
  • Mitra Farzin
چکیده

Background and aims. Because of compromised angulations of implants, the abutments are sometimes prepared. The purpose of this study was to investigate the effect of removing one wall of the implant abutment on the retention of cement-retained crowns. Materials and methods. Four prefabricated abutments were attached to analogues and embedded in acrylic resin blocks. The first abutment was left intact. Axial walls were partially removed from the remaining abutments to produce abutments with three walls. The screw access channel for the first and second abutments were completely filled with composite resin. For the third and fourth abutments, only partial filling was done. Wax-up models were made by CAD/CAM. Ten cast copings were fabricated for each abutment. The copings of fourth abutment had an extension into the screw access channel. Copings were cemented with Temp Bond. The castings were removed from the abutment using an Instron machine, and the peak removal force was recorded. A one-way ANOVA was used to test for a significant difference followed by the pairwise comparisons. Results. The abutments with opened screw access channel had a significantly higher retention than the two other abutments. The abutment with removed wall and no engagement into the hole by the castings exhibited the highest retention. Conclusion. Preserving the opening of screw access channel significantly increases the retention where one of the axial walls of implant abutments for cement-retained restorations is removed during preparation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...

متن کامل

Effect of Abutment Modification and Cement Type on Retention of Cement-Retained Implant Supported Crowns

OBJECTIVE Provisional cements are commonly used to facilitate retrievability of cement-retained fixed implant restorations; but compromised abutment preparation may affect the retention of implant-retained crowns.The purpose of this study was to investigate the effect of abutment design and type of luting agent on the retentive strength of cement-retained implant restorations. MATERIALS AND M...

متن کامل

Effect of Circumferential and Axial Grooves on the Retention of Provisionally Cement-Retained Implant-Supported Crowns

Introduction: Retention of provisionallycemented implant-supported restorations plays an important role in success of the treatment. Uncemented restorations may cause several problems such as restoration swallowing, increased bone loss and prosthesis failure. Therefore, suitable cement compromising between retention and retrievability as well as extra-means of abutment retention might be prefer...

متن کامل

مقایسه گیر بین کستینگ‌های کراون و بریج ساخته شده از پلاستیک کوپینگ و وکس آپ مستقیم در سه سیستم ایمپلنت

  Background and Aims: Adequate retention has significant importance in the prognosis of implant supported cemented the restorations. Limited literature had evaluated the effect of direct wax up or use of plastic coping on the retention of these restorations. This aims of this study was to compare the retention of castings fabricated by the plastic coping and direct wax up for single crown and ...

متن کامل

بررسی تاثیرخشونت سطحی اباتمنت بر میزان استحکام گیر رستوریشنهای سمان شونده متکی بر ایمپلنت با سمان موقتی

 Background and Objective: Surface roughness can increase the retention of castings by sandblast that are micro retentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement.  Materials and Methods: Thirty abutments (DIO implant- Cemented abutment,SAC 4814N(II)) were divided in three groups, first ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015