A prospective multicenter clinical trial of 3i machined-surface implants: results after 6 years of follow-up.

نویسندگان

  • Dietmar Weng
  • Zhimon Jacobson
  • Dennis Tarnow
  • Markus B Hürzeler
  • Ove Faehn
  • Farshid Sanavi
  • Pål Barkvoll
  • Renée M Stach
چکیده

PURPOSE In this prospective multicenter clinical study, 1,179 3i standard threaded and self-tapping implants were followed for up to 6 years and monitored according to established success criteria. MATERIALS AND METHODS A total of 493 patients (240 men and 253 women) with a mean age of 45.1 years at implant surgery were enrolled at 6 research centers after being screened for exclusion criteria. Implants were placed according to a 2-stage surgical protocol with a minimum of 4 months of submerged healing in the mandible and 6 months in the maxilla. Restorations included 633 prostheses, the majority of which were fixed partial dentures in the posterior mandible or maxilla or single-tooth replacements in the anterior maxilla. RESULTS One hundred four implants (8.8%) did not meet success criteria and were designated as failures, and 222 implants (18.8%) were lost to follow-up. The cumulative success rate according to life table methods was 91.1% at 6 years. DISCUSSION Sixty percent of the failed implants were short (< or = 10 mm long), and their cumulative success rate as a group at 6 years was 89.0%, compared to 93.1% for longer implants (P < .05). Thirty-three percent of all failures were implants placed in the posterior maxilla, for a 5-year cumulative success rate of 87.4%. CONCLUSION It appears that limited bone dimensions and poor-quality bone have an impact on the performance of these machined-surface implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective multicenter evaluation of 1,583 3i implants: 1- to 5-year data.

PURPOSE The purpose of this prospective multicenter study was to evaluate the efficacy of 3i threaded implants for the treatment of edentulous patients in a 1- to 5-year period. This article reports the total data and global results of 3 threaded designs of 3i implants: self-tapping, ICE, and Osseotite. MATERIALS AND METHODS A total of 1,583 implants (619 ICE, 545 Osseotite, and 419 self-tapp...

متن کامل

The self-tapping and ICE 3i implants: a prospective 3-year multicenter evaluation.

This multicenter prospective clinical evaluation was undertaken to determine the therapeutic success and marginal bone level stability of 3i's self-tapping and ICE implants after 3 years of prosthetic loading. Between July 1995 and June 1996, 189 completely or partially edentulous patients were treated with 614 machined-surface screw-type commercially pure titanium implants (self-tapping or ICE...

متن کامل

Outcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial

Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...

متن کامل

Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study

Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...

متن کامل

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2003