Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: A fatigue simulation study.

نویسندگان

  • Caitlin Martin
  • Wei Sun
چکیده

Transcatheter aortic valve (TAV) intervention is now the standard-of-care treatment for inoperable patients and a viable alternative treatment option for high-risk patients with symptomatic aortic stenosis. While the procedure is associated with lower operative risk and shorter recovery times than traditional surgical aortic valve (SAV) replacement, TAV intervention is still not considered for lower-risk patients due in part to concerns about device durability. It is well known that bioprosthetic SAVs have limited durability, and TAVs are generally assumed to have even worse durability, yet there is little long-term data to confirm this suspicion. In this study, TAV and SAV leaflet fatigue due to cyclic loading was investigated through finite element analysis by implementing a computational soft tissue fatigue damage model to describe the behavior of the pericardial leaflets. Under identical loading conditions and with identical leaflet tissue properties, the TAV leaflets sustained higher stresses, strains, and fatigue damage compared to the SAV leaflets. The simulation results suggest that the durability of TAVs may be significantly reduced compared to SAVs to about 7.8 years. The developed computational framework may be useful in optimizing TAV design parameters to improve leaflet durability, and assessing the effects of underexpanded, elliptical, or non-uniformly expanded stent deployment on TAV durability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Severe Aortic Regurgitation in Degenerative Bioprosthetic Aortic Homograft Treated by Valve in Valve

Bioprosthetic valves are increasingly used in patients with aortic valve stenosis. In comparison with mechanical valves, these valves have a lower risk of thromboembolism and no need for anticoagulation [1,2]. However, the durability is limited; the best current valves are expected to degenerate in 10 to 20 years, resulting in stenosis or regurgitation or combined pathology. Surgical aortic val...

متن کامل

Transcatheter aortic valve replacement failure: déjà vu ou jamais vu?

T he past half decade has seen transcatheter aortic valve replacement (TAVR) emerge as the standard of care for inoperable and high-risk patients with severe aortic stenosis: randomized data have demonstrated reduced mortality with TAVR compared with medical therapy or surgery in these respective situations. Accordingly, recent research efforts have reorientated from establishing the short-term...

متن کامل

Fast Valve Degeneration after Transcatheter Aortic Valve Replacement in a Hemodialysis Patient

Transcatheter aortic valve replacement (TAVR) for severe aortic stenosis has been proven to be a safe therapeutic and well-established option in patients at high and intermediate surgical risk. TAVR shows a comparable mid-term durability compared to surgical aortic valve replacement. Only minimal data exist in the long-term survival of dialysis patients after cardiac valve replacement. Long-ter...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 48 12  شماره 

صفحات  -

تاریخ انتشار 2015