Can peak expiratory flow be measured accurately during a forced vital capacity manoeuvre?
نویسندگان
چکیده
Spirometry and peak flow measurements traditionally depend on different forced expiratory manoeuvres and have usually been performed on separate, dedicated equipment. As spirometry becomes more widely used in primary care settings, the authors wished to determine whether there was a systematic difference between peak expiratory flow (PEF) derived from a short sharp exhalation (PEF manoeuvre) and from a full forced vital capacity (FVC) manoeuvre, using the same turbine spirometer (Microloop, Micro Medical, Kent, UK). Eighty children (38 with current asthma) aged 7-16 yrs were asked to perform 2 blocks of PEF and FVC manoeuvres, the order being randomly assigned. PEF obtained from a peak flow manoeuvre (PEFPF) was significantly greater than that from a forced vital capacity manoeuvre (PEFVC) in both healthy (group mean difference 20 L x min(-1); p<0.001) and asthmatic children (group mean difference 9 L.min(-1); p<0.004). For clinical purposes, a mean difference of about 3% for children with asthma is of no practical significance, and peak expiratory flow data can usefully be obtained during spirometric recordings.
منابع مشابه
Dependence of forced vital capacity manoeuvre on time course of preceding inspiration in patients with restrictive lung disease.
In normal subjects and patients with airway obstruction, flows during a forced vital capacity (FVC) manoeuvre are higher after a fast inspiration without an end-inspiratory pause (manoeuvre 1) as compared to a slow inspiration with an end-expiratory pause of approximately 5 s (manoeuvre 2). In this study, we investigated the influence of these manoeuvres on maximal expiratory volume-time and fl...
متن کاملPerformance of forced expiratory manoeuvre in children.
The negative expiratory pressure (NEP) method has been previously used to assess the performance of forced vital capacity (FVC) manoeuvre in normal adults. The aim of the present study is to assess whether flow limitation is achieved during FVC manoeuvres in children aged 6-14 yrs. NEP (-10 cmH2O) was successfully applied in 177 normal children, the portion of FVC over which expiratory flow did...
متن کاملA comparison of a new transtelephonic portable spirometer with a laboratory spirometer.
The Spirophone is a new, portable transtelephonic spirometer which records the slow and the forced expiratory vital capacity tests. Data can be transmitted via the telephone to a remote receiving centre, where a volume-time curve and the flow-volume curve are displayed on screen in real time. The aim of this study was to compare the newly developed transtelephonic spirometer, with a laboratory ...
متن کاملComparison of abdominal muscle activity and peak expiratory flow between forced vital capacity and fast expiration exercise
[Purpose] The purpose of this investigation was to compare the activities of the abdominal muscles and peak expiratory flow between forced vital capacity and fast expiration exercise. [Subjects and Methods] Fifteen healthy male participated in this study. Peak expiratory flow and electromyographic activities of the rectus abdominis, external oblique, and internal oblique/transversus abdominis m...
متن کاملPeak inspiratory flow and inspiratory vital capacity of patients with asthma measured with and without a new dry-powder inhaler device (Turbuhaler).
In 101 asthmatic adults with varying degrees of bronchial obstruction, lung function tests including peak inspiratory flow (PIF), inspiratory vital capacity (IVC), peak expiratory flow (PEF), forced vital capacity (FVC), and forced expiratory volume in one second (FEV1) measurements were made. Significant correlations between inspiratory and expiratory volumes were found. In most patients, PIF ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 16 4 شماره
صفحات -
تاریخ انتشار 2000