Distortion correction and cross-talk compensation algorithm for use with an imaging spectrometer based spatially resolved diffuse reflectance system.
نویسندگان
چکیده
Optical spectroscopy of human tissue has been widely applied within the field of biomedical optics to allow rapid, in vivo characterization and analysis of the tissue. When designing an instrument of this type, an imaging spectrometer is often employed to allow for simultaneous analysis of distinct signals. This is especially important when performing spatially resolved diffuse reflectance spectroscopy. In this article, an algorithm is presented that allows for the automated processing of 2-dimensional images acquired from an imaging spectrometer. The algorithm automatically defines distinct spectrometer tracks and adaptively compensates for distortion introduced by optical components in the imaging chain. Crosstalk resulting from the overlap of adjacent spectrometer tracks in the image is detected and subtracted from each signal. The algorithm's performance is demonstrated in the processing of spatially resolved diffuse reflectance spectra recovered from an Intralipid and ink liquid phantom and is shown to increase the range of wavelengths over which usable data can be recovered.
منابع مشابه
The Importance of Reflectance Terminology in Imaging Spectroscopy
Analysing databases, field and airborne spectrometer data, modelling studies and publications, it becomes obvious, that there is a lack of consistency in definitions of reflectance quantities throughout the imaging spectroscopy user community. One example is the term ‘BRDF’ assigned to significantly differing quantities, ranging from the bidirectional reflectance distribution function to hemisp...
متن کاملMethods for the surface reflectance retrieval from CHRIS/PROBA data over land and inland waters
The Compact High Resolution Imaging Spectrometer (CHRIS) on board the Project for On–Board Autonomy (PROBA) platform system provides the first high spatial resolution hyperspectral/multiangular remote sensing data from a satellite system, what represents a new source of information for Earth Observation purposes. When dealing with the retrieval of surface reflectance from such kind of hyperspec...
متن کاملRadiative transport in the delta-P1 approximation for semi-infinite turbid media.
We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations and the standard diffusion approximation. We demonstrate that the delta-P1 app...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملError Analysis of Spectral Reflectance Derived from Imaging Spectrometer Data’
As the field of remote imaging spectrometry grows, interest increases in applications that require the data be “corrected” to surface reflectance. However, the utility of the data for these applications will be limited by the accuracy to which the correction can be performed. Two approaches to atmospheric compensation are reviewed and applied to airbome spectrometer data to study their error ch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 87 12 شماره
صفحات -
تاریخ انتشار 2016