Compensatory functions of two alkyl hydroperoxide reductases in the oxidative defense system of Legionella pneumophila.

نویسندگان

  • Jason J LeBlanc
  • Ross J Davidson
  • Paul S Hoffman
چکیده

Legionella pneumophila expresses two catalase-peroxidase enzymes that exhibit strong peroxidatic but weak catalatic activities, suggesting that other enzymes participate in decomposition of hydrogen peroxide (H2O2). Comparative genomics revealed that L. pneumophila and its close relative Coxiella burnetii each contain two peroxide-scavenging alkyl hydroperoxide reductase (AhpC) systems: AhpC1, which is similar to the Helicobacter pylori AhpC system, and AhpC2 AhpD (AhpC2D), which is similar to the AhpC AhpD system of Mycobacterium tuberculosis. To establish a catalatic function for these two systems, we expressed L. pneumophila ahpC1 or ahpC2 in a catalase/peroxidase mutant of Escherichia coli and demonstrated restoration of H2O2 resistance by a disk diffusion assay. ahpC1::Km and ahpC2D::Km chromosomal deletion mutants were two- to eightfold more sensitive to H2O2, tert-butyl hydroperoxide, cumene hydroperoxide, and paraquat than the wild-type L. pneumophila, a phenotype that could be restored by trans-complementation. Reciprocal strategies to construct double mutants were unsuccessful. Mutant strains were not enfeebled for growth in vitro or in a U937 cell infection model. Green fluorescence protein reporter assays revealed expression to be dependent on the stage of growth, with ahpC1 appearing after the exponential phase and ahpC2 appearing during early exponential phase. Quantitative real-time PCR showed that ahpC1 mRNA levels were approximately 7- to 10-fold higher than ahpC2D mRNA levels. However, expression of ahpC2D was significantly increased in the ahpC1 mutant, whereas ahpC1 expression was unchanged in the ahpC2D mutant. These results indicate that AhpC1 or AhpC2D (or both) provide an essential hydrogen peroxide-scavenging function to L. pneumophila and that the compensatory activity of the ahpC2D system is most likely induced in response to oxidative stress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

Redundant hydrogen peroxide scavengers contribute to Salmonella virulence and oxidative stress resistance.

Salmonella enterica serovar Typhimurium is an intracellular pathogen that can survive and replicate within macrophages. One of the host defense mechanisms that Salmonella encounters during infection is the production of reactive oxygen species by the phagocyte NADPH oxidase. Among them, hydrogen peroxide (H(2)O(2)) can diffuse across bacterial membranes and damage biomolecules. Genome analysis ...

متن کامل

The Different Antibacterial Impact of Silver Nanoparticles Against Legionella pneumophila Compared to Other Microorganisms

Legionella pneumophila is the pathogen responsible for severe pneumonia known as Legionnaires’ disease. Legionella can live under varied stress conditions, especially in cold environments, and is common in many artificial environments. In this study, the antimicrobial activity of biogenic silver nanoparticles, prepared using the culture supernatant of Klebsiella pneumoniae, was evaluated agains...

متن کامل

An Investigation of the Legionella Pneumophila Infection in Pneumonic Patients in Three Different Infections Hospital Wards in Tehran

Legionella pneumophila is one of the causative agent of pneumonia in human being. In recent years many reports has been come from different parts of world regarding infectivity of this organism. This disease occurs almost because of contamination of air conditioning systems. For the purpose of assessment of the legionella pneumophila in pneumonic patients, 200 specimen from sputum and tracheo-b...

متن کامل

فراوانی لژیونلا پنوموفیلا در شیر آب سرد و گرم و مخزن آب انکوباتورهای بخش نوزادان بیمارستانهای گیلان

Background and purpose: Nosocomial outbreaks of legionnaires’ diseases are usually related to contamination of water sources. This survey investigated the frequency of mip gene in cold and warm water taps and water containers of infant incubators containing legionella pneumophila in hospitals of Guilan province, Iran. Materials and methods: This cross-sectional study used 140 samples. They wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of bacteriology

دوره 188 17  شماره 

صفحات  -

تاریخ انتشار 2006