Use of the Architect-i2000 estradiol immunoassay during in vitro fertilization.

نویسندگان

  • Joëlle Taieb
  • Clarisse Benattar
  • Rokhaya Diop
  • Anne Sophie Birr
  • Albert Lindenbaum
چکیده

reported by other researchers using enzymatic methods, e.g., a within-run CV (n ϭ 11) of 4.4% at 80 ␮mol/L (10) and a between-run CV (n ϭ 12) of 10.4% at 75 ␮mol/L (7). Analytical recovery was examined using plasma specimens (160 ␮L each) from a reference pool containing 30.6 ␮mol/L mannose. Samples were supplemented with 40 ␮L of water, 500 ␮mol/L mannose, or 1 mmol/L man-nose. Each supplementation was performed in triplicate and yielded recoveries of 104.0% for the lower-concentration mannose samples and 102.6% for the higher-concentration samples. We studied potential interference from endogenous substances using a plasma pool (mannose concentration, 79 ␮mol/L) obtained from healthy volunteers. A one-tenth volume of the solution containing a possible inter-ferent was added to the plasma. Glucose at 50 mmol/L, fructose at 200 ␮mol/L, free plus conjugated bilirubin at 340 ␮mol/L, hemoglobin at 5.0 g/L, uric acid at 600 ␮mol/L, and ascorbic acid at 20 mmol/L did not affect the measured mannose values. The mean plasma mannose concentration of 15 samples from healthy individuals (10 from females and 5 from males), collected in the morning after fasting, was 35.6 Ϯ 12.6 ␮mol/L. The mean glucose concentration of the same plasma samples was 4.64 Ϯ 0.87 mmol/L. The observed mannose value was comparable to those reported by other investigators: e. Both mannose and glucose concentrations in plasma samples (n ϭ 21) from nondiabetic and diabetic patients were measured. A close positive correlation (r ϭ 0.779; P Ͻ0.01) was observed between mannose and glucose concentrations. Our data are consistent with those reported previously (6, 7). We also measured the mannose and glucose concentrations in plasma samples collected at 0, 30, 60, and 120 min after oral administration of 75 g of glucose to healthy, 14-h fasted volunteers (two females and three males). The plasma mannose concentration gradually decreased until at least 120 min after glucose ingestion, whereas the glucose concentration increased transiently, as is widely known (Table 1). To the best of our knowledge, this is the first report of the time course of changes in the plasma mannose concentration under physiologic conditions. We are now studying the mechanism of the change in the plasma mannose concentration induced by glucose load. Simultaneous determination of arabitol and mannose by gas-liquid chromatography in experimental candi-diasis. Relationships between glucose and mannose during late gestation in normal pregnancy and pregnancy complicated by diabetes mellitus: concurrent concentrations in maternal plasma and …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance characteristics of eight estradiol immunoassays.

Measurement of estradiol is useful in assisted reproduction, evaluation of infertility, menopause, and male feminization. The analytic performance of 8 estradiol immunoassays was evaluated. The imprecision and accuracy of the Access, ADVIA Centaur, ARCHITECT i2000, AutoDELFIA, Elecsys 2010, IMMULITE 2000, and Vitros ECi estradiol assays (see text for proprietary information) were evaluated by u...

متن کامل

P-89: The Developmental Rates of Early Mouse Embryos Derived from In Vitro Fertilization of Mature Oocytes Obtained from Ovarian Stimulation Using A Combination of HMG and Estradiol Valerate

Background: In recent years, a combination of hormones and agents in assisted reproductive technology (ART) cycles as a means of stimulating the ovary and developing more follicles. With respect to the positive effects of Estradiol Valerate on reproductive tissues and the impact on native genes of the egg that transferred to the embryo after fertilization, it seems that this agent can also effe...

متن کامل

Performance evaluation and cross-reactivity from insulin analogs with the ARCHITECT insulin assay.

BACKGROUND Insulin measurement is used for the diagnosis of hypoglycemia and for insulin pharmacokinetic evaluations. We assessed the analytical and clinical performance of the ARCHITECT insulin assay, a chemiluminescent immunoassay recently introduced for the ARCHITECT i2000 fully automated immunoassay analyzer (Abbott Laboratories). We also tested whether major insulin analogs cross-reacted w...

متن کامل

Clinical performance evaluation of four automated chemiluminescence immunoassays for hepatitis C virus antibody detection.

Various automated chemiluminescence immunoassay (CLIA) analyzers for the detection of antibodies to hepatitis C virus (HCV) are now commercially available in clinical laboratories and are replacing conventional enzyme immunoassays. We investigated the performance of four anti-HCV CLIAs (the Architect Anti-HCV assay on the Architect i2000 system, the Vitros Anti-HCV assay on the Vitros ECiQ Immu...

متن کامل

Direct enzyme immunoassay of estradiol in serum of women enrolled in an in vitro fertilization and embryo transfer program.

We present a fast and simple direct enzyme immunoassay for the sexual steroid hormone estradiol-17 beta in serum of women enrolled in an in vitro fertilization and embryo transfer program. We added 25 microL of standards or samples and 125 microL of a mixture of monoclonal antibody and displacing agents to the wells of a microtiter plate previously coated with a second antibody. After 30 min 50...

متن کامل

P-181: The Effect of Estradiol Valerate and rFSH Combination As Ovarian Stimulator on In Vitro Fertilization and Embryo Developmental Rate of Ovulated Oocytes in Mice

Background: Sex steriods play important roles in the growth and differentiation of reproduction tissues and in maintatinance of pregnancy. 17-β oestradiol (E2) is the most important one of them that has a positive effect an the granulosa cells proliferation and ovarian follicle maturation. Then the aim of this study was determine of the effectes of rFSH+ E2 combination as an ovarian stimulator ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2003