Rapid detection of mycobacteria in clinical specimens by using the automated BACTEC 9000 MB system and comparison with radiometric and solid-culture systems.

نویسندگان

  • G E Pfyffer
  • C Cieslak
  • H M Welscher
  • P Kissling
  • S Rüsch-Gerdes
چکیده

Recovery rates of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens were determined by using the fluorescent BACTEC 9000 MB system. Data were compared to those assessed by the radiometric BACTEC 460 system and by cultivation on solid media. A total of 3,095 specimens were processed with N-acetyl-L-cysteine-NaOH by two laboratories. The contamination rates for the BACTEC 9000 MB system were 6.8% (center 1) and 9.8% (center 2). A total of 451 mycobacterial isolates were detected (Mycobacterium tuberculosis complex, n = 296; nontuberculous mycobacteria [NTM], n = 155). These isolates originated from 94 (20.8%) smear-positive and 357 (79.2%) smear-negative specimens. The BACTEC 9000 MB system was significantly better than solid media (P < 0.05) in detecting AFB, but it was less efficient than the radiometric system (P < 0.01). The BACTEC 9000 MB system plus solid media (combination A) recovered 393 (87.1%) of the isolates, while the BACTEC 460 system plus solid media (combination B) detected 430 (95.3%) of all AFB isolates. Between combination A and B there was no statistically significant difference for the detection of isolates from smear-positive specimens (P > 0.05), in contrast to the recovery of AFB from smear-negative specimens for M. tuberculosis complex, P < 0.05; for NTM, P < 0.01). The mean time to detection of M. tuberculosis complex was 12.2 days for smear-positive specimens and 18.1 days for smear-negative specimens with the BACTEC 9000 MB system; 9.3 and 15.6 days, respectively, with the BACTEC 460 system; and 21.2 and 28.4 days, respectively, with solid media. For NTM, the average detection times were 15.1, 17.3, and 31.3 days by the three methods, respectively. In conclusion, the BACTEC 9000 MB system is a rapid, less labor-intensive detection system which allows for higher levels of recovery of AFB than solid media. There is no risk of cross contamination, which is known to be the case for the BACTEC 460 system, and data management is greatly facilitated. As a whole, however, the BACTEC 9000 MB system should only be used in conjunction with solid media.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the MB/BacT system and comparison to the BACTEC 460 system and solid media for isolation of mycobacteria from clinical specimens.

The MB/BacT automated system is designed for the isolation of mycobacteria from clinical specimens. It utilizes a colorimetric sensor and reflected light to continuously monitor the CO2 concentration in the culture medium. We compared its performance to that of the BACTEC 12B media for the radiometric BACTEC 460 instrument and that of solid culture media. Respiratory specimens and urine samples...

متن کامل

Two liquid medium systems, mycobacteria growth indicator tube and MB redox tube, for Mycobacterium tuberculosis isolation from sputum specimens.

Two manual liquid medium systems, the Mycobacteria Growth Indicator Tube (MGIT) and MB Redox tube systems, were evaluated in comparison to the radiometric BACTEC-460 semiautomated system for recovery of Mycobacterium tuberculosis from sputum specimens. The highest level of recovery, from a total of 77 culture-positive specimens, occurred with the BACTEC-460 system (92.2%), followed by the MB Re...

متن کامل

Comparison of the BACTEC MGIT 960 and BACTEC 460TB systems for detection of mycobacteria in clinical specimens.

The reliability of the Mycobacteria Growth Indicator Tube (MGIT) 960 system for rapid detection of mycobacteria in clinical specimens was evaluated and compared to the radiometric method (BACTEC 460TB) and to mycobacterial culture on Lowenstein-Jensen (LJ) medium. Clinical specimens (n = 590) were tested without selection. A total of 121 (20.5%) isolates of mycobacteria were recovered; 98 (81.0...

متن کامل

Comparison of three isolation systems for the culture of mycobacteria from respiratory and non-respiratory samples.

AIMS To compare the recovery of mycobacteria from clinical samples using the MB/BacT rapid culture system with that obtained using egg medium or the Bactec radiometric method. METHODS The three methods were compared using 681 clinical samples (462 respiratory and 219 non-respiratory samples) and eight external quality control strains. Culture media were incubated at 35-37 degrees C for six we...

متن کامل

Comparison of BACTEC MGIT 960 system and BACTEC 460 TB system for growth and detection of Mycobacteria from clinical specimens.

This study was carried out to compare the performance of BACTEC MGIT 960 with the BACTEC 460 TB for growth and detection of Mycobacteria from human clinical specimens. The BACTEC MGIT 960 instrument is a fully automated system that utilizes MGIT tubes containing an oxygen sensor embedded in silicon at the bottom and filled with 7 mL of modified Middlebrook 7H9 broth. Identical samples were inoc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 1997