Hospital-acquired legionellosis: solutions for a preventable infection.

نویسندگان

  • Miguel Sabria
  • Victor L Yu
چکیده

Hospital-acquired Legionnaires' disease has been reported from many hospitals since the first outbreak in 1976. Although cooling towers were linked to the cases of Legionnaires' disease in the years after its discovery, potable water has been the environmental source for almost all reported hospital outbreaks. Microaspiration is the major mode of transmission in hospital-acquired Legionnaires' disease; showering is not a mode of transmission. Since the clinical manifestations are non-specific, and specialised laboratory testing is required, hospital-acquired legionellosis is easily underdiagnosed. Discovery of a single case of hospital-acquired Legionnaires' disease is an important sentinel of additional undiscovered cases. Routine environmental culture of the hospital water supply for legionella has proven to be an important strategy in prevention. Documentation of legionella colonisation in the water supply would increase physician index of suspicion for Legionnaires' disease and the necessity for in-house legionella test methods would be obvious. Legionella is a common commensal of large-building water supplies. Preventive maintenance is commonly recommended; unfortunately, this measure is ineffective in minimising legionella colonisation of building water supplies. Copper-silver ionisation systems have emerged as the most successful long-term disinfection method for hospital water disinfection systems. There is a need for public-health agencies to educate the public and media that discovery of cases identifies those hospitals as providers of superior care, and that such hospitals are not negligent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental culturing for Legionella: can we build a better mouse trap?

The drinking water of hospitals has been directly linked to the occurrence of hospital-acquired legionellosis. In addition, the mode of transmission is now known to be primarily aspiration rather than aerosolization. Legionellosis is now recognized as a patient safety concern for nosocomial infection. In 2009, Centers for Medicaid and Medicare Services raised the issue that hospitals might no l...

متن کامل

Prevention of hospital-acquired legionellosis.

PURPOSE OF REVIEW The incidence of hospital-acquired legionellosis appears to be increasing. Presence of Legionella in the hospital drinking water is the only risk factor known with certainty to be predictive of risk for contracting Legionnaires' disease. RECENT FINDINGS Given the high frequency of infection by nonpneumophila and nonserogroup 1 species, both Legionella respiratory culture on ...

متن کامل

Isolation of Legionella pneumophila from clinical & environmental sources in a tertiary care hospital.

BACKGROUND & OBJECTIVES Legionella pneumophila and other members of this genus are important respiratory pathogens but legionellosis often remains a neglected and under reported condition. Hence, this study was done to find out the presence of this organism in patients admitted to a tertiary care hospital with community-acquired pneumonia (CAP). METHODS A total of 470 lower respiratory tract ...

متن کامل

Community-acquired pneumonia due to Legionella pneumophila, the utility of PCR, and a review of the antibiotics used

INTRODUCTION There are at least 40 types of Legionella bacteria, half of which are capable of producing disease in humans. The Legionella pneumophila bacterium, the root cause of Legionnaires' disease, causes 90% of legionellosis cases. CASE PRESENTATION We describe the case of a 60-year-old woman with a history of diabetes mellitus and arterial hypertension who was admitted to our hospital w...

متن کامل

Microbiological investigations on a nosocomial case of Legionella pneumophila pneumonia associated with water birth and review of neonatal cases.

A case of Legionella pneumophila 1 pneumonia, confirmed by positive serology and urinary antigen, occurred in a 7-day old neonate after water birth in hospital. As respiratory samples were not available for culture, further microbiological investigations were performed in neonate and environment, in order to recognize the source of infection. The hospital water supply was contaminated by L. pne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Lancet. Infectious diseases

دوره 2 6  شماره 

صفحات  -

تاریخ انتشار 2002