Digital Mammography with a Photon Counting Detector in a Scanned Multislit Geometry
نویسنده
چکیده
Mammography screening aims to reduce the number of breast cancer deaths by early detection of the disease, which is one of the leading causes of deaths for middle aged women in the western world. The risk from the x-ray radiation in mammography is relatively low but still a factor in the benefit-risk ratio of screening. The characterization and optimization of a digital mammography system is presented in this thesis. The investigated system is shown to be highly dose efficient by employing a photon counting detector in a scanning multislit geometry. A novel automatic exposure control (AEC) is proposed and validated in clinical practise. The AEC uses the leading detector edge to measure the transmission of the breast. The exposure is modulated by altering the scan velocity during the scan. A W-Al anode-filter combination is proposed. The characterization of the photon counting detector is performed using the detective quantum efficiency. The effect of the photon counting detector and the multislit geometry on the measurement method is studied in detail. It is shown that the detector has a zero-frequency DQE of over 70% and that it is quantum limited even at very low exposures. Efficient rejection of image-degrading secondary radiation is fundamental for a dose efficient system. The efficiency of the scatter rejection techniques currently used are quantified and compared to the multislit geometry. A system performance metric with its foundation in statistical decision theory is discussed. It is argued that a photon counting multislit system can operate at approximately half the dose compared to several other digital mammography techniques.
منابع مشابه
Clinical Evaluation of a Photon-Counting Tomosynthesis Mammography System
Digital breast tomosynthesis promises solutions to many of the problems currently associated with projection mammography, including elimination of artifactual densities from the superposition of normal tissues and increasing the conspicuity of true lesions that would otherwise be masked by superimposed normal tissue. We have investigated the performance of a novel tomosynthesis system in a clin...
متن کاملCharacterization and Optimization of Silicon-strip Detectors for Mammography and Computed Tomography
The goal in medical x-ray imaging is to obtain the image quality required for a given detection task, while ensuring that the patient dose is kept as low as reasonably achievable. The two most common strategies for dose reduction are: optimizing incident x-ray beams and utilizing energy information of transmitted beams with new detector techniques (spectral imaging). In this thesis, dose optimi...
متن کاملDetectors for Digital Mammography 2
The X-ray detector is the heart of a digital mammography system. Its improved characteristics of dynamic range and signal-to-noise ratio provide inherent advantages over screen-fi lm technology. Detector technologies used for digital mammography can be distinguished by the acquisition geometry into scanning or full-fi eld detectors, by energy conversion mechanism into phosphor-based and nonphos...
متن کاملX-ray Imaging Using a Hybrid Photon Counting GaAs Pixel Detector
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 μm thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consists of a matrix of 64 x 64 identical square pixels (170 μm x 170 μm) and covers a total area of 1.2 cm. The electronics in each cell comprises a prea...
متن کاملDetective quantum efficiency dependence on x-ray energy weighting in mammography.
An evaluation of the dependence of detective quantum efficiency (DQE) on the incident energy spectrum has been made for mammography. The DQE dependence on the energy spectrum has been evaluated for energy-integrating detectors, photon-counting detectors, and detectors that measure the energy of each photon. To isolate the effect of the x-ray energy spectrum the detector has been assumed to be i...
متن کامل