MedLinac2: a GEANT4 based software package for radiotherapy.
نویسندگان
چکیده
Dose distribution evaluation in oncological radiotherapy treatments is an outstanding problem that requires sophisticated computing technologies to optimize the clinical results (i.e. increase the dose to the tumour and reduce the dose to the healthy tissues). Nowdays, dose calculation algorithms based on the Monte Carlo method are generally regarded as the most accurate tools for radiotherapy. The flexibility of the GEANT4 (GEometry ANd Tracking) Monte Carlo particle transport simulation code allows a wide range of applications, from high-energy to medical physics. In order to disseminate and encourage the use of Monte Carlo method in oncological radiotherapy, a software package based on the GEANT4 Monte Carlo toolkit has been developed. The developed package (MedLinac2) allows to simulate in an adequate flexible way a linear accelerator for radiotherapy and to evaluate the dose distributions.
منابع مشابه
X-ray tracing using Geant4
We describe an extension to the Geant4 software package that allows it to be used as a general purpose X-ray tracing package. We demonstrate its use by building a model of the X-ray optics of the XMM-Newton, calculating its effective area, and comparing the results with the published calibration curves.
متن کاملThe LCFIVertex Package: vertex detector-based Reconstruction at the ILC
The contribution gives an overview of the LCFIVertex package, providing software tools for high-level event reconstruction at the International Linear Collider using vertexdetector information. The package was validated using a fast Monte Carlo simulation. Performance obtained with a more realistic GEANT4-based detector simulation and realistic tracking code is presented. The influence of hadro...
متن کاملDevelopment of a Phase Space Generator software for Medical Linear Accelerator Applications
Introduction: During the last decades, simulation of radiation therapy treatment conditions in treatment room for studying with more details in comparison with treatment planning system (TPS) is taken into consideration. The most problem with starting these kind of researches is the geometry of Medical linacs and verification of the accelerators. Therefore, researchers tried to...
متن کاملMeasurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code.
Radiation therapy is an established method of cancer treatment. New technologies in cancer radiotherapy need a more accurate computation of the dose delivered in the radiotherapy treatment plan. This study presents some results of a Geant4-based application for simulation of the absorbed dose distribution given by a medical linear accelerator (LINAC). The LINAC geometry is accurately described ...
متن کاملSimulating the High Energy Gamma-ray Sky Seen by the Glast Large Area Telescope
This paper presents the simulation of the GLAST high energy gamma-ray telescope. The simulation package, written in C++, is based on the Geant4 toolkit, and it is integrated into a general framework used to process events. A detailed simulation of the electronic signals inside Silicon detectors has been provided and it is used for the particle tracking, which is handled by a dedicated software....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annali dell'Istituto superiore di sanita
دوره 46 2 شماره
صفحات -
تاریخ انتشار 2010