Evaluation of Composite Mesh for Ventral Hernia Repair

نویسندگان

  • Jim F. Byrd
  • Neal Agee
  • Phuong H. Nguyen
  • Jessica J. Heath
  • Kwan N. Lau
  • Iain H. McKillop
  • David Sindram
  • John B. Martinie
  • David A. Iannitti
چکیده

INTRODUCTION Composite mesh prostheses incorporate the properties of multiple materials for ventral hernia repair. This study evaluated a polypropylene/ePTFE composite mesh with a novel internal polydioxanone (PDO) absorbable ring. METHODS Composite mesh was placed intraperitoneally in 16 pigs through an open laparotomy and explanted at 2, 4, 8, and 12 weeks. Intraabdominal adhesions were measured laparoscopically. Host tissue in-growth was assessed histologically and tensiometrically. Degradation of the internal PDO ring component was also measured tensiometrically. Appropriate statistical tests were used, and P ≤.05 indicated significance. RESULTS No adhesions were formed in 50% of the grafts explanted at 8 weeks and 25% of grafts explanted at 12 weeks. There were significantly more vascular structures at 8 weeks, 73.5 ± 28, compared with 2 weeks, 6.75 ± 2 (P ≤.01). The T-peel force at the mesh-host tissue interface was not significantly different among time points. The absorbable PDO ring underwent complete degradation by 12 weeks. CONCLUSIONS This composite mesh was associated with minimal intraabdominal adhesions, progressive in-growth of host tissues, and complete degradation of a novel internal PDO ring that aided mesh positioning. This composite hernia mesh showed a favorable performance in a porcine model of open ventral hernia repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative efficacy of Prolene and Prolene-Vicryl composite mesh for experimental ventral hernia repair in dogs

In this study, efficacy of two hernia mesh implants viz. conventional Prolene and a novel Prolene-Vicryl composite mesh was assessed for experimental ventral hernia repair in dogs. Twelve healthy mongrel dogs were selected and randomly divided into three groups, A, Band C (n=4). In all groups, an experimental laparotomy was performed; thereafter, the posterior rectus sheath and peritoneum were ...

متن کامل

Preclinical evaluation of the effect of the combined use of the Ethicon Securestrap® Open Absorbable Strap Fixation Device and Ethicon Physiomesh™ Open Flexible Composite Mesh Device on surgeon stress during ventral hernia repair

Aim To evaluate whether performing ventral hernia repairs using the Ethicon Physiomesh™ Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap® Open Absorbable Strap Fixation Device reduces surgical time and surgeon stress levels, compared with traditional surgical repair methods. Methods To repair a simulated ventral incisional hernia, two surgeries were performed by...

متن کامل

Polyester Composite Versus PTFE in Laparoscopic Ventral Hernia Repair

INTRODUCTION Both polyester composite (POC) and polytetrafluoroethylene (PTFE) mesh are commonly used for laparoscopic ventral hernia repair. However, sparse information exists comparing perioperative and long-term outcome by mesh repair. METHODS A prospective database was utilized to identify 116 consecutive patients who underwent laparoscopic ventral hernia repair at The Mount Sinai Hospit...

متن کامل

Significant improvement of biocompatibility of polypropylene mesh for incisional hernia repair by using poly-ε-caprolactone nanofibers functionalized with thrombocyte-rich solution

Incisional hernia is the most common postoperative complication, affecting up to 20% of patients after abdominal surgery. Insertion of a synthetic surgical mesh has become the standard of care in ventral hernia repair. However, the implementation of a mesh does not reduce the risk of recurrence and the onset of hernia recurrence is only delayed by 2-3 years. Nowadays, more than 100 surgical mes...

متن کامل

A multicenter prospective study of patients undergoing open ventral hernia repair with intraperitoneal positioning using the monofilament polyester composite ventral patch: interim results of the PANACEA study

PURPOSE This study assessed the recurrence rate and other safety and efficacy parameters following ventral hernia repair with a polyester composite prosthesis (Parietex™ Composite Ventral Patch [PCO-VP]). PATIENTS AND METHODS A single-arm, multicenter prospective study of 126 patients undergoing open ventral hernia repair with the PCO-VP was performed. Patient outcomes were assessed at discha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011