Fatigue testing median sternotomy closures.

نویسندگان

  • A R Casha
  • M Gauci
  • L Yang
  • M Saleh
  • P H Kay
  • G J Cooper
چکیده

OBJECTIVE Sternal dehiscence is commonly due to wire cutting through bone. With a biological model, we measured the rate of cutting through bone, of standard steel wire closure, peristernal steel wire, figure-of-eight closure, polyester and sternal bands sternotomy closure techniques. METHODS Polyester, figure-of-eight, peristernal and sternal band closures were tested against standard closure eight times using adjacent paired samples, to eliminate biological variables. Fatigue testing was performed by a computerized materials-testing machine, cycling between loads of 1 and 10 kg. The displacements at maximum and minimum loads were measured during each cycle. Cutting through, manifested by the displacement at the maximum load between the 1st and 150th cycles was measured. The percentage cut-through of each closure method versus standard closure was calculated. RESULTS The differences in the displacement between each of the polyester (1.01 mm), figure-of-eight (0.52 mm), peristernal (0.72 mm) and sternal band (0.66 mm) groups versus standard closure (0.22, 0.22, 2.1, 3.2 mm) in the paired samples were statistically significant (Student's paired t-test; P<0.01). There were statistically significant differences in the percentage cut-through of polyester, figure-of-eight, peristernal and sternal bands (ANOVA, P<0.001), versus standard closure. CONCLUSIONS In our sheep sternum model, we have quantified the differing rate of cutting through bone of five types of median sternotomy closure techniques. We have controlled for bone variables by testing each closure versus standard closure using paired adjacent bone samples. Peristernal and sternal band closure techniques are significantly superior to standard closure. The use of polyester and figure-of-eight closures requires caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1010-7940(01)00807-7

We read with interest the recent article by Casha et al. [1] on fatigue testing median sternotomy closures. Their model is based on 2.5-cm cut samples of sheep sternal bones, wired in the standard trans-sternal, ®gure-eight, and peristernal fashion; additionally, no. 5 gauge polyester and stainless steel bands were used. The authors conclude that use of polyester and ®gure-eight closures requir...

متن کامل

Fatigue testing of three peristernal median sternotomy closure techniques

BACKGROUND Failure of a sternotomy closure because of closure system fatigue is a complication that may result in dehiscence and put the individual at risk for serious complications. The purpose of this study was to assess the fatigue performance of three peristernal median sternotomy closure techniques (figure-of-eight stainless-steel wires, figure-of-eight stainless-steel cables, or Pectofix ...

متن کامل

Thymectomy by Partial Sternotomy for the Treatment of Non-Thymomatous Myasthenia Gravis

Background: Myasthenia gravis is an autoimmune disease characterized by weakness and fatigue of voluntary muscles. Thymectomy is considered an effective therapeutic option for patients with myasthenia gravis. The purpose of this study is to evaluate the efficacy of thymectomy by partial sternotomy for the treatment of non-thymomatous myasthenia gravis. Materials and Methods: From 2002 to 2006, ...

متن کامل

Evaluation of Thymic Changes after Median Sternotomy in Children

In patients who undergo median sternotomy to treat congenital heart diseases, a thymectomy is performed to yield better access to the cardiac system. In this study we have used MRI to evaluate the changes in size, shape and location of the thymus after midsternatomy. This case-control study was performed during 2011-2012 in Shiraz, Iran. Eligible participants between 5-17 years of age were divi...

متن کامل

EMG-based Fatigue Assessment During Endurance Testing With Different VT Protocols

BACKGROUND: Muscle fatigue can be defined as the failure of a muscle to maintain a reasonably expected force output. The multivariate approach to fatigue assessment is used because the multiple (EMG) feature provides more information than anyone. OBJECTIVE: This study presents a method of assessing muscle fatigue during endurance testing at 50% maximal voluntary contraction (MVC) using electro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2001