Evaluation of the biological effect of Ti generated debris from metal implants: ions and nanoparticles.

نویسندگان

  • J Soto-Alvaredo
  • E Blanco
  • J Bettmer
  • D Hevia
  • R M Sainz
  • C López Cháves
  • C Sánchez
  • J Llopis
  • A Sanz-Medel
  • M Montes-Bayón
چکیده

Metallic implants placed in humans exhibit wear and corrosion that result in the liberation of metal-containing by-products. In the case of titanium (Ti) containing implants, the metal containing debris may exist in a number of states, including metallic particles produced by mechanical wear and the products of metal corrosion in biological environments, such as the joints and surrounding fluids and tissues. In addition, these constituents may dissolve in both intracellular and extracellular solutions generating Ti ions. Both species, ions and nanoparticles, show different cellular toxicities. In this work we have evaluated the possible evolution of TiO2 nanoparticles (NPs) into soluble Ti metal ions by contact with biological fluids. For this aim, an in vitro study to address quantitative Ti solubilisation from TiO2 nanoparticles (with a diameter of 21 nm) after incubation with human serum at different concentrations has been conducted. Total Ti determination revealed low solubilisation rates ranging from 0.53 to 0.82% after just one week of incubation in the serum. The incubated serum was then subjected to speciation analysis by anion exchange liquid chromatography using an inductively coupled plasma mass spectrometer (ICP-MS) as an elemental detector for Ti monitoring. The obtained results revealed a significant increase in the Ti signal associated with the fraction of the protein transferrin and preferentially with one of the metal binding sites of the protein, the N-lobe. Thus, the effect of Ti at the cellular level has been evaluated by considering that it can be present either as ions or as nanoparticles using two different cells lines: human enterocytes HT29 and murine osteoblasts MC3T3. Significant toxicity was found at the highest concentration assayed (50 μg mL(-1)) for both Ti species (ions and NPs) and slightly higher for the ionic species at lower concentrations (1 and 10 μg mL(-1)).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells.

Hip resurfacing with cobalt-chromium (CoCr) alloy was developed as a surgical alternative to total hip replacement. However, the biological effects of nanoparticles generated by wear at the metal-on-metal articulating surfaces has limited the success of such implants. The aim of this study was to investigate the effects of the combined exposure to CoCr nanoparticles and cobalt ions released fro...

متن کامل

Characterization and Assessment of Antimicrobial Activity and Potential of Heavy Metal ion Detection of Silver Nanoparticles synthesized from Actinidia deliciosa paste using double distilled water and 70% ethanol as solvent

Green synthesis of nanoparticles using plants as sources exhibiting superiority over the physical and chemical methods that are expensive and can involve the use of toxic, hazardous chemicals, which may pose biological and environmental risks. In present study silver nanoparticles were synthesized in single step by biological method using extracts of Actinidia deliciosa paste as reducing and st...

متن کامل

Trojan-Like Internalization of Anatase Titanium Dioxide Nanoparticles by Human Osteoblast Cells

Dentistry and orthopedics are undergoing a revolution in order to provide more reliable, comfortable and long-lasting implants to patients. Titanium (Ti) and titanium alloys have been used in dental implants and total hip arthroplasty due to their excellent biocompatibility. However, Ti-based implants in human body suffer surface degradation (corrosion and wear) resulting in the release of meta...

متن کامل

Toxicity of cobalt-chromium nanoparticles released from a resurfacing hip implant and cobalt ions on primary human lymphocytes in vitro.

Adverse tissue responses to prostheses wear particles and released ions are important contributors to hip implant failure. In implant-related adverse reactions T-lymphocytes play a prominent role in sustaining the chronic inflammatory response. To further understand the involvement of lymphocytes in metal-on-metal (MoM) implant failure, primary human lymphocytes were isolated and treated with c...

متن کامل

Adult Stem Cells Properties in Terms of Commitment, Aging and Biological Safety of Grit-Blasted and Acid-Etched Ti Dental Implants Surfaces

Titanium (Ti) is one of the most widely used biomaterials for manufacturing dental implants. The implant surface properties strongly influence osseointegration. The aim of the present study was to in vitro investigate the characteristics of Ti dental implants in terms of mutagenicity, hemocompatibility, biocompatibility, osteoinductivity and biological safety. The Ames test was used to test the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Metallomics : integrated biometal science

دوره 6 9  شماره 

صفحات  -

تاریخ انتشار 2014