Analysis of stem tip pain in revision total knee arthroplasty.

نویسندگان

  • Christine I Kimpton
  • Andrew David Crocombe
  • William Neil Bradley
  • Brigstocke Gavin Huw Owen
چکیده

Stem tip pain following revision total knee arthroplasty is a significant cause of patient dissatisfaction, which in the presence of an aseptic well-fixed component has no widely accepted surgical solution. A definitive cause of stem tip pain remains elusive, however it has been suggested that high stress concentrations within the region of the stem tip may play a role. This paper reports a finite element study of a novel clinical technique where a plate is attached to the tibia within the region of the stem tip to reduce stem tip pain. The results demonstrate that the plate reduces stress concentrations in the bone at the stem tip of the implant. The magnitude of stress reduction is dependent upon plate location, material and attachment method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome of revision in comparison with primary total knee arthroplasty in Iran

 Abstract  Background: In the recent decade, many primary total knee arthroplasties have  been carried out in Iran and the number of revision cases is expected to rise with the  aging population. The aim of this study was to report the outcome of revision surgery  in the country and make a comparison between the outcome of revision and that of  the primary arthroplasty.  Methods: Retrospectivel...

متن کامل

Pain at the Tip of the Stem after Revision Total Knee Arthroplasty

Objective: To correlate parameters of implants with incidence of pain. Methods: 32 knees (31 patients) operated on between 2006 to 2008 in a serie of cases of TKA revision surgery were monitored for evidence of pain at the tip of the stem.In all we used uncemented stem Scorpio TS Total Knee ® Revision System (Stryker ®). Criteria assessed: pain in the leg or thigh without other causes, diameter...

متن کامل

Tibial Component in Revision of Total Knee Arthroplasty: Comparison between Cemented and Hybrid Fixation

OBJECTIVE To compare the clinical, radiographic and medium-term follow-up results from two fixation methods for the tibial component in revision procedures on total knee prostheses: cemented (tray and stem) and hybrid (cemented tray and uncemented, nonporous canal-filling stem). METHODS Between August 1999 and November 2005, 30 revision procedures on total knee arthroplasties were performed o...

متن کامل

Ten-Year Results of Primary and Revision Condylar-Constrained Total Knee Arthroplasty in Patients with Severe Coronal Plane Instability

OBJECTIVE To retrospectively review the results at minimum ten years after surgery of a consecutive series of total knee arthroplasties (TKAs) performed using a constrained condylar implant in patients with severe coronal plane instability. MATERIALS AND METHODS The series comprised of 44 patients (45 knees) who received primary (19 knees) or revision (26 knees) TKA with a constrained condyla...

متن کامل

Knee arthrodesis in failed total knee arthroplasty with severe osteolysis and ipsilateral long-stem total hip arthroplasty.

We report a case of knee fusion after a failed total knee arthroplasty (TKA) with severe osteolysis including the epicondyle and ipsilateral total hip arthroplasty (THA) with long Wagner revision stem (Sulzer Orthopedics, Baar, Switzerland). The conventional devices for arthrodesis were unavailable in this case because of the long Wagner revision stem and poor bone stock. A connector was made b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2013