Effect of Single Off-Axis Implant Placement on Abutment Screw Stability Under Lateral Loading.
نویسندگان
چکیده
PURPOSE The aim of this study was to evaluate the effect of off-axis implant placement in relation to the prosthetic crown on abutment screw loosening under different directions of twisting moments. MATERIALS AND METHODS Twenty-one implant assemblies were divided equally into three groups (n = 7). Each assembly consisted of an internal-octagon implant measuring 4.1 × 12 mm (standard plus implants) with corresponding 5.5-mm synocta abutments (Straumann) mounted in an epoxy resin-glass fiber composite. Group A had a straight implant configuration in relation to the prosthetic crown and was subjected to clockwise twisting moment (control). The other two groups, B and C, with off-axis implant placement were subjected to clockwise and counterclockwise moments, respectively. A lateral load of 80 N was applied to the specimens for 1 × 10(6) cycles at 90 degrees to the long axis of the implant. The loading point was 4 mm from the center of the implant in group A and 6 mm in groups B and C. The reverse torque value (RTV) of the abutment screw was measured before and after loading. Data were analyzed using a paired samples t test and one-way analysis of variance (ANOVA) at a significance level of α = .05. RESULTS An increase in postloading RTV was found relative to preloading RTV in all groups, but was only significant in group A (P < .05). The mean reverse torque difference (RTD) was higher in group A (3.17 ± 1.04 Ncm), followed by groups B (1.03 ± 1.41 Ncm) and C (0.43 ± 1.09 Ncm). A significant difference in RTD was noted between group A and the remaining groups (P < .05). However, no significant difference was found between groups B and C (P > .05). CONCLUSION Placement of an implant in an off-axis relation to the prosthetic crown resulted in significantly lower reverse torque values compared with straight implant configuration. However, the extent of reduction in Ncm is small and is considered clinically insignificant in the studied implant system. Furthermore, no significant difference was found in RTV between clockwise and counterclockwise twisting moments.
منابع مشابه
Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value
Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملComparative study of antirotational single tooth abutments.
Identifying the functional and mechanical limitations of single tooth implant systems is essential for the long-term success of the restoration. Three designs with different prosthetic connections were evaluated with their corresponding single tooth abutments for structural integrity and cyclic fatigue. The internal implant octagon was the weakest connection under off-axis impact loading and la...
متن کاملProsthetic and biomechanical factors affecting bone remodeling around implants.
Bone remodeling and, consequently, soft tissue levels around osseointegrated implants may be influenced by many variables that are considered of prosthetic or biomechanical nature: implant-abutment connection type and geometry (external vs internal), timing of abutment connection (at uncovering vs delayed), abutment material (titanium vs gold vs ceramic), abutment shape and dimensions (convex v...
متن کاملComparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling
Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 31 3 شماره
صفحات -
تاریخ انتشار 2016