Imaging the intact mouse cornea using coherent anti-stokes Raman scattering (CARS).
نویسندگان
چکیده
PURPOSE The aim of this study was to image the cellular and noncellular structures of the cornea and limbus in an intact mouse eye using the vibrational oscillation of the carbon-hydrogen bond in lipid membranes and autofluorescence as label-free contrast agents. METHODS Freshly enucleated mouse eyes were imaged using two nonlinear optical techniques: coherent anti-Stokes Raman scattering (CARS) and two-photon autofluorescence (TPAF). Sequential images were collected through the full thickness of the cornea and limbal regions. Line scans along the transverse/sagittal axes were also performed. RESULTS Analysis of multiple CARS/TPAF images revealed that corneal epithelial and endothelial cells could be identified by the lipid-rich plasma membrane CARS signal. The fluorescent signal from the collagen fibers of the corneal stroma was evident in the TPAF channel. The transition from the cornea to sclera at the limbus was marked by a change in collagen pattern (TPAF channel) and thickness of surface cells (CARS channel). Regions within the corneal stroma that lack collagen autofluorescence coincided with CARS signal, indicating the presence of stromal fibroblasts or nerve fibers. CONCLUSIONS The CARS technique was successful in imaging cells in the intact mouse eye, both at the surface and within corneal tissue. Multiphoton images were comparable to histologic sections. The methods described here represent a new avenue for molecular specific imaging of the mouse eye. The lack of need for tissue fixation is unique compared with traditional histology imaging techniques.
منابع مشابه
Coherent anti-Stokes Raman holography for chemically selective single-shot nonscanning 3D imaging.
We propose and develop a new way for nonscanning coherent anti-Stokes Raman scattering (CARS) imaging by using CARS holography, which can capture, at a single shot, both the amplitude and the phase of a coherent Raman image. It hence allows for chemically selective three-dimensional imaging at a laser pulse duration limited speed, which is not possible to achieve by using any of the existing la...
متن کاملCoherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Coherent anti-Stokes Raman scattering (CARS) microscopy permits vibrational imaging with high-sensitivity, high speed, and three-dimensional spatial resolution. We review recent advances in CARS microscopy, including experimental design, theoretical understanding of contrast mechanisms, and applications to chemical and biological systems. We also review the development of multiplex CARS microsp...
متن کاملMultiplex Coherent Anti-Stokes Raman Scattering Microspectroscopy and Study of Lipid Vesicles
We report a theoretical description and experimental implementation of multiplex coherent anti-Stokes Raman scattering (M-CARS) microspectroscopy using a picosecond pump beam and a femtosecond Stokes beam. The effect of the chirp in the Stokes pulse on a M-CARS spectrum is studied. Polarization-sensitive detection is utilized for suppression of the nonresonant background and for selective detec...
متن کاملLabel-free imaging of lipid dynamics using Coherent Anti-stokes Raman Scattering (CARS) and Stimulated Raman Scattering (SRS) microscopy.
The recently developed Coherent Anti-stokes Raman Scattering (CARS) microscopy and Stimulated Raman Scattering (SRS) microscopy have provided new methods to visualize the localization and regulation of biological molecules without the use of invasive and potentially perturbative labels. They allow rapid imaging of specific molecules with high resolution and sensitivity. These tools have been ef...
متن کاملCoherent anti-Stokes Raman scattering microscopy using tightly focused radially polarized light.
We report a radially polarized coherent anti-Stokes Raman scattering (RP-CARS) microscopy for facilitating longitudinally oriented molecules detection. We observe that under tight focusing of radially polarized pump and Stokes light fields with a high-NA objective, RP-CARS radiation from molecules oriented along the longitudinal direction is approximately threefold stronger than that using line...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 54 8 شماره
صفحات -
تاریخ انتشار 2013