Radiometric Calibration Methodology of the Landsat 8 Thermal Infrared Sensor

نویسندگان

  • Matthew Montanaro
  • Allen Lunsford
  • Zelalem Tesfaye
  • Brian Wenny
  • Dennis Reuter
چکیده

The science-focused mission of the Landsat 8 Thermal Infrared Sensor (TIRS) requires that it have an accurate radiometric calibration. A calibration methodology was developed to convert the raw output from the instrument into an accurate at-aperture radiance. The methodology is based on measurements obtained during component-level and instrument-level characterization testing. The radiometric accuracy from the pre-flight measurements was estimated to be approximately 0.7%. The calibration parameters determined pre-flight were updated during the post-launch checkout period by utilizing the on-board calibration sources and Earth scene data. These relative corrections were made to adjust for differences between the pre-flight and the on-orbit performance of the instrument, thereby correcting large striping artifacts observed in Earth imagery. Despite this calibration correction, banding artifacts (low frequency variation in the across-track direction) have been observed in certain uniform Earth scenes, but not in other uniform scenes. In addition, the absolute calibration performance determined from vicarious measurements have revealed a time-varying error to the absolute radiance reported by TIRS. These issues were determined to not be caused by the calibration process developed for the instrument. Instead, an investigation has revealed that stray light is affecting the recorded signal from the Earth. The varying optical stray light effect is an ongoing subject of evaluation and investigation, and a correction strategy is being devised that will be added to the calibration process. Remote Sens. 2014, 6 8804

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Landsat-8 Thermal Infrared Sensor (TIRS) Vicarious Radiometric Calibration

Launched in February 2013, the Landsat-8 carries on-board the Thermal Infrared Sensor (TIRS), a two-band thermal pushbroom imager, to maintain the thermal imaging capability of the Landsat program. The TIRS bands are centered at roughly 10.9 and 12 μm (Bands 10 and 11 respectively). They have 100 m spatial resolution and image coincidently with the Operational Land Imager (OLI), also on-board L...

متن کامل

An Overview of In-orbit Radiometric Calibration of Typical Satellite Sensors

This paper reviews the development of in-orbit radiometric calibration methods in the past 40 years. It summarizes the development of in-orbit radiometric calibration technology of typical satellite sensors in the visible/near-infrared bands and the thermal infrared band. Focuses on the visible/near-infrared bands radiometric calibration method including: Lamp calibration and solar radiationbas...

متن کامل

Radiometric cross-calibration of the Landsat-7 ETM+ and Landsat-5 TM sensors based on tandem data sets

Early in its mission, the Landsat-7 spacecraft was temporarily placed in a ‘‘tandem’’ orbit very close to that of the Landsat-5 spacecraft in order to facilitate the establishment of sensor calibration continuity between the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) and Landsat-5 Thematic Mapper (TM) sensors. The key period for the tandem configuration was June 1–4, 1999, during which hund...

متن کامل

Radiometric Cross Calibration of Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+)

This study evaluates the radiometric consistency between Landsat-8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+) using cross calibration techniques. Two approaches are used, one based on cross calibration between the two sensors using simultaneous image pairs, acquired during an underfly event on 29–30 March 2013. The other approach is based on using time seri...

متن کامل

Geothermal area detection using Landsat 8 operational land imager and thermal infrared sensor data in Ardabil province, Iran

GIS and remote sensing technique with using Landsat 8 images data are very important methods for detection of geothermal resources. In this study, Land Surface Temperature (LST) for Ardabil province in northwest of Iran, was derived with the use of Landsat 8 Operational Land Imager (OLI) of 30 m spatial resolution and Thermal Infrared Sensor (TIRS) data of 100 m spatial resolution. We consider ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Remote Sensing

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014