The design and response of ground source heat pumps coupled to vertical closed loop arrays in UK domestic applications are investigated in this article. Two typical UK house types are selected as the vehicle for the study and a detailed dynamic thermal modelling method is used to arrive at time-series heating demands for the two houses. A new empirical heat pump model is derived using experimental data taking into account the deteriorating performance of the heat pump during periods of light load. The heat pump model is incorporated into an existing numerical ground model and completed with a classical effectiveness type heat exchange model of the closed loop array. The model is used to analyse array sizing and performance over an extended time period, as well as sensitivity of the design to soil conductivity and borehole heat exchanger resistance and sensitivity to over-sizing and part-load behavior of the heat pump. Results show that the UK’s standard for ground source design (the Microgeneration Certification Scheme) may lead to under-estimated array sizes and that heating system over-sizing and deleterious part-load heat pump performance can add up to 20% to the electrical consumption of these systems.
منابع مشابه
Gir 72
Ground source heat pumps are receiving increasing interest in North America and in some countries in Europe. The technology is well established with over 400 000 units (80% of which are domestic) installed worldwide and about 45 000 installed annually although most systems in the United States are of the reversible type. Very few systems have been installed in the UK. Efficiencies for ground so...
متن کاملEconomic optimization and comparative study of solar heat pumps
In this paper, an economic study of solar heat pumps and an investigation of differences between solar heat pumps and conventional heat pumps—based on their performances and energy consumption—are conducted for a residential apartment located in Austin, Texas, USA. Heating in the apartment is provided via a solar heat pump during the cold months of a year. Solar collectors are used to meet the ...
متن کامل01 The conceptual design of the photovoltaic solar thermal collector hybrid system and the ground source heat pump to provide electricity, heating and cooling a residential building focusing on technical, economic and environmental parameters.
This paper attempts to present and compare four solar assisted ground source heat pump combined systems with series and parallel layouts and direct and indirect heat exchange in Zahedan in order to supply part of the electricity demand for equipment and selling surplus electricity to the grid as a source of project financing and revenue generation for residents, moreover, fulfill the region's n...
متن کاملSimulation of a Domestic Ground Source Heat Pump System Using a Transient Numerical Borsehole Heat Exchanger Model
Common approaches to the simulation of Borehole Heat Exchangers (BHEs) assume heat transfer in circulating fluid and grout to be in a quasi-steady state and ignore fluctuations in fluid temperature due to transport of the fluid around the loop. However, in domestic ground source heat pump systems, the heat pump and circulating pumps switch on and off during a given hour; therefore the effect of...
متن کاملDomestic heat pumps in the UK: user behaviour, satisfaction and performance
Consumer adoption of microgeneration technologies is part of the UK strategy to reduce carbon emissions from buildings. Domestic heat pumps are viewed as a potentially important carbon saving technology, given the ongoing decarbonisation of the electricity supply system. To address the lack of independent evaluation of heat pump performance, the Energy Saving Trust undertook the UK’s first larg...
متن کامل