Distribution characteristics of normal pure-tone thresholds.

نویسندگان

  • Robert H Margolis
  • Richard H Wilson
  • Gerald R Popelka
  • Robert H Eikelboom
  • De Wet Swanepoel
  • George L Saly
چکیده

OBJECTIVE This study examined the statistical properties of normal air-conduction thresholds obtained with automated and manual audiometry to test the hypothesis that thresholds are normally distributed and to examine the distributions for evidence of bias in manual testing. DESIGN Four databases were mined for normal thresholds. One contained audiograms obtained with an automated method. The other three were obtained with manual audiometry. Frequency distributions were examined for four test frequencies (250, 500, 1000, and 2000 Hz). STUDY SAMPLE The analysis is based on 317 569 threshold determinations of 80 547 subjects from four clinical databases. RESULTS Frequency distributions of thresholds obtained with automated audiometry are normal in form. Corrected for age, the mean thresholds are within 1.5 dB of reference equivalent threshold sound pressure levels. Frequency distributions of thresholds obtained by manual audiometry are shifted toward higher thresholds. Two of the three datasets obtained by manual audiometry are positively skewed. CONCLUSIONS The positive shift and skew of the manual audiometry data may result from tester bias. The striking scarcity of thresholds below 0 dB HL suggests that audiologists place less importance on identifying low thresholds than they do for higher-level thresholds. We refer to this as the Good enough bias and suggest that it may be responsible for differences in distributions of thresholds obtained by automated and manual audiometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی دقت تخمین آستانه شنوایی بهنجار بوسیله پاسخ‌های برانگیخته قشر شنوایی

Background: Cortical Evoked Response Audiometry (CERA) refers to prediction of behavioral pure-tone thresholds (500-4000 Hz) obtained by recording the N1-P2 complex of auditory long latency responses. CERA is the preferred method for frequency–specific estimation of audiogram in conscious adults and older children. CERA has an increased accuracy of determination of the hearing thresholds of ale...

متن کامل

Comparative study between pure tone audiometry and auditory steady-state responses in normal hearing subjects.

INTRODUCTION Auditory steady-state responses (ASSR) are an important tool to detect objectively frequency-specific hearing thresholds. Pure-tone audiometry is the gold-standard for hearing evaluation, although sometimes it may be inconclusive, especially in children and uncooperative adults. AIM Compare pure tone thresholds (PT) with ASSR thresholds in normal hearing subjects. MATERIALS AND...

متن کامل

The Relevance of the High Frequency Audiometry in Tinnitus Patients with Normal Hearing in Conventional Pure-Tone Audiometry

OBJECTIVE The majority of tinnitus patients suffer from hearing loss. But a subgroup of tinnitus patients show normal hearing thresholds in the conventional pure-tone audiometry (125 Hz-8 kHz). Here we explored whether the results of the high frequency audiometry (>8 kHz) provide relevant additional information in tinnitus patients with normal conventional audiometry by comparing those with nor...

متن کامل

Effect of Exposure to a Mixture of Organic Solvents on Hearing Thresholds in Petrochemical Industry Workers

Introduction: Hearing loss is one of the most common occupational diseases. In most workplaces, workers are exposed to noise and solvents simultaneously, so the potential risk of hearing loss due to solvents may be attributed to noise.  In this study we aimed to assess the effect of exposure to mixed aromatic solvents on hearing in the absence of exposure to hazardous noise.   Materials and Met...

متن کامل

Theory and practice of pure tone audiometry

Pure tone audiometry indicates what hearing thresholds (dB) are required to just be able to perceive a tone at different frequencies (Hz). A pure tone audiology threshold at a specific frequency is the decibel level at which a sound is perceived 50% of the time. The decibel scale used in pure tone audiometry is dB Hearing Level (dB HL). The dB HL intensity scale is based on normal human hearing...

متن کامل

یافته‌های پاسخ برانگیخته پایدار شنوایی در بزرگسالان مبتلا به نوروپاتی/ناهمزمانی شنوایی

    Background & Aim: Auditory steady state response(ASSR) is an auditory evoked response that has received a lot of attention nowadays. At present, ASSR is mostly used to estimate pure-tone thresholds. Clinical evidence of ASSR in combination with findings for auditory middle latency response (AMLR) and 40 Hz response support the assumption that based on stimulus modulation rate, the ASSR anat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of audiology

دوره 54 11  شماره 

صفحات  -

تاریخ انتشار 2015