Fretting is known to be a major cause of contact deterioration and failure, particularly in tin-plated contacts. During fretting the contact resistance generally increases slowly with time. Superimposed on this slow increase in contact resistance are rapid changes in contact resistance within fractions of a second, called intermittences or short duration discontinuities. Although intermittences have been reported by several authors, they are frequently overlooked in traditional fretting experiments and not much is known about their origin. The present study aims at filling this gap. A test apparatus has been built to measure the contact voltage-drop profile during an intermittence and fretting experiments on tin-plated copper contacts have been carried out. The results lead to a set of requirements for a model to explain intermittency phenomena.
منابع مشابه
Micro ACTION PIN Compliant-Pin Connectors: Advancing the State of the Art in Press-Fit Technology
Micro ACTION PIN (MAP) connectors from Tyco Electronics have taken through-hole connector technology to a new level— significantly reducing hole diameters compared to previous designs, while retaining the assembly and operational advantages of press-fit connectors. Equally important, the inherent design attributes of MAP connectors offer electrical performance comparable to, or better than, con...
متن کاملProbabilistic signatures of spatiotemporal intermittency in the coupled sine circle map lattice
The phase diagram of the coupled sine circle map lattice exhibits a variety of interesting phenomena including spreading regions with spatiotemporal intermittency, non-spreading regions with spatial intermittency, and coherent structures termed solitons. A cellular automaton mapping of the coupled map lattice maps the spreading to non-spreading transition to a transition from a probabilistic to...
متن کاملFinal Project Summary — PEER Lifelines Program
1. Project goals and objectives This project aimed at developing analytical models and methods for assessing the seismic response of electrical substation equipment connected by assemblies of rigid bus (RB) and flexible strap connectors (FSC) or slider connectors (SC). Also developed is a method to estimate the reliability of electrical substation systems subjected to stochastic earthquake load...
متن کاملThe Evaluation of Wear in the Fretting of Electrical Contact Surfaces
Consideration is given to methods for the evaluation of surface wear from fretted electrical contact surfaces. The surfaces under consideration are selected for in-vivo applications, they are testing using purpose built fretting apparatus to investigate intermittency. The intermittency is associated with high frequency transients in the contact resistance between the two interfaces. These event...
متن کاملGenerator of Connectors for Sofa/dcup Annotation Generator of Connectors for Sofa/dcup Generátor Konektorù pro Sofa/dcup
The aim of the thesis was to design and implement generator of connectors for SOFA/DCUP architecture, which would, based on description of application architecture and its deployment specification, generate code skeletons for connectors used in the application. The generated code should reflect the specification of architectural model of SOFA/DCUP connectors. Because of problems identified in t...