Method for the noninvasive measurement of intraocular pressure in mice.

نویسندگان

  • John Danias
  • Antti I Kontiola
  • Theodoros Filippopoulos
  • Thom Mittag
چکیده

PURPOSE To evaluate the applicability of rebound tonometry for measurement of IOP in the mouse eye. METHODS An induction-impact (I/I) tonometer, which operates on the rebound principle, was scaled down and adapted to determine IOP of the mouse eye. IOP measurement using this concept is based on contacting the eye with a probe and detecting the motion as the probe collides with the eye and bounces back. The motion parameters of the probe vary according to eye pressure and are used to calculate IOP. A prototype instrument was constructed for measurement of IOP in mouse eyes, and its ability to accurately and reliably measure IOP was tested by comparing the measurements against the manometric (true) IOP determined in cannulated mouse eyes ex vivo. The I/I tonometer was also used to measure IOP in vivo in anesthetized adult C57BL/6 mice. RESULTS A strong correlation between the true IOP and the I/I measurements (R(2) = 0.95) was found for IOPs in the range of 3.7 to 44.1 mm Hg in cannulated mouse eyes. Repeat determinations in individual eyes showed a low degree of variability in the relationship of the measured IOP with the true IOP. In anesthetized mice, mean IOP +/- SD as determined by rebound tonometry was 9.8 +/- 3.9 mm Hg when the animals were anesthetized with ketamine alone and 7.6 +/- 1.9 mm Hg when a mixture of ketamine, acepromazine, and xylazine was used. Contralateral eyes differed by 0.9 +/- 2.5 and 0.1 +/- 2.7 mm Hg, respectively, for the two anesthetic regimens. CONCLUSIONS The I/I tonometer can be used for noninvasive, in vivo IOP measurement in mouse eyes. The availability of an easy-to-use, reliable tonometer for IOP measurements in mice will allow more extensive use of the mouse as a model for glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Noninvasive intraocular pressure measurements in mice by pneumotonometry.

PURPOSE To develop a reliable, noninvasive, continuous, and easily implemented system for measuring intraocular pressure (IOP) in mice. METHODS Pneumotonometry was adapted for measurement of mouse IOP. Measurements were compared with those obtained with the servo-null micropipette system (SNMS) and with direct anterior chamber cannulation. Heart rate was monitored by the precordial pulse, EKG...

متن کامل

What is the Real Cause of Glaucoma?

Introduction: The term glaucoma refers to a group of diseases that have a characteristic optic neuropathy with associated visual field loss in common. Intraocular pressure has been considered to be the only causal factor for glaucoma and the only factor that can be manipulated to alter the course of the disease. But considering high intraocular pressure as the only factor responsible for glauco...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

تخمین بدون کاف فشارخون مبتنی بر ویژگی‌های زمانی سیگنال نبض

Blood pressure is one of the vital signs. Specially, it is crucial for some cases such as hypertension patients and it should be monitored continuously in ICU/CCU. It must be noted that current systems to measure blood pressure, often require trained operators. As an example, in post-hospital cares, blood pressure control is difficult except with the presence of a nurse or use of a device that ...

متن کامل

Evaluation of various factors relating to intraocular pressure and C/D ratio

Introduction: Intraocular pressure (IOP) is determined by three factors: the rate of aqueous humor production by the ciliary’s body, the resistances to aqueous out flow across the trabecular meshwork and the level of episcleral vessel pressure. IOP varies with a number of factors, including: age, sex, race, systemic disease and diurnal variation. The purpose of this study is measurement of IO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 44 3  شماره 

صفحات  -

تاریخ انتشار 2003