BACKGROUND AND PURPOSE Flow diverters are increasingly used in the endovascular treatment of intracranial aneurysms. Our aim was to determine neurologic complication rates following Pipeline Embolization Device placement for intracranial aneurysm treatment in a real-world setting. MATERIALS AND METHODS We retrospectively evaluated all patients with intracranial aneurysms treated with the Pipeline Embolization Device between July 2008 and February 2013 in 17 centers worldwide. We defined 4 subgroups: internal carotid artery aneurysms of ≥10 mm, ICA aneurysms of <10 mm, other anterior circulation aneurysms, and posterior circulation aneurysms. Neurologic complications included spontaneous rupture, intracranial hemorrhage, ischemic stroke, permanent cranial neuropathy, and mortality. Comparisons were made with t tests or ANOVAs for continuous variables and the Pearson χ(2) or Fisher exact test for categoric variables. RESULTS In total, 793 patients with 906 aneurysms were included. The neurologic morbidity and mortality rate was 8.4% (67/793), highest in the posterior circulation group (16.4%, 9/55) and lowest in the ICA <10-mm group (4.8%, 14/294) (P = .01). The spontaneous rupture rate was 0.6% (5/793). The intracranial hemorrhage rate was 2.4% (19/793). Ischemic stroke rates were 4.7% (37/793), highest in patients with posterior circulation aneurysms (7.3%, 4/55) and lowest in the ICA <10-mm group (2.7%, 8/294) (P = .16). Neurologic mortality was 3.8% (30/793), highest in the posterior circulation group (10.9%, 6/55) and lowest in the anterior circulation ICA <10-mm group (1.4%, 4/294) (P < .01). CONCLUSIONS Aneurysm treatment with the Pipeline Embolization Device is associated with the lowest complication rates when used to treat small ICA aneurysms. Procedure-related morbidity and mortality are higher in the treatment of posterior circulation and giant aneurysms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk Factors for Hemorrhagic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the International Retrospective Study of the Pipeline Embolization Device.

BACKGROUND AND PURPOSE Spontaneous intraparenchymal hemorrhage is a dreaded complication of unknown etiology following flow-diversion treatment. Using the International Retrospective Study of the Pipeline Embolization Device registry, we studied demographic, aneurysm, and procedural characteristics associated with intraparenchymal hemorrhage following Pipeline Embolization Device treatment. M...

متن کامل

Platelet Testing is Associated with Worse Clinical Outcomes for Patients Treated with the Pipeline Embolization Device.

BACKGROUND AND PURPOSE The necessity for platelet-inhibition testing before aneurysm treatment in patients premedicated with antiplatelet agents is controversial. Using the International Retrospective Study of Pipeline Embolization Device registry, we studied complication rates in groups of patients who underwent platelet testing and those who did not undergo platelet testing to determine if th...

متن کامل

CASE SERIES Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study

Background and purpose The Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic ...

متن کامل

Pipeline Embolization Device in the Treatment of Recurrent Previously Stented Cerebral Aneurysms.

BACKGROUND AND PURPOSE The use of the Pipeline Embolization Device in the management of recurrent previously stented cerebral aneurysms is controversial. The aim of this study was to evaluate the efficacy and safety of the Pipeline Embolization Device in the treatment of recurrent, previously stented aneurysms. MATERIALS AND METHODS Twenty-one patients with previously stented recurrent aneury...

متن کامل

Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study

BACKGROUND AND PURPOSE The Pipeline Embolization Device (PED) has become a routine first-line option for treatment of intracranial aneurysms (IAs). We assessed the early safety and technical success of a new version of PED, Pipeline Flex Embolization Device with Shield Technology (Pipeline Shield), which has the same design and configuration but has been modified to include a surface synthetic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2015