Outcomes of accessory renal artery occlusion during endovascular aneurysm repair.

نویسندگان

  • Jagajan Karmacharya
  • Shane S Parmer
  • James N Antezana
  • Ronald M Fairman
  • Edward Y Woo
  • Omaida C Velazquez
  • Michael A Golden
  • Jeffrey P Carpenter
چکیده

OBJECTIVE Accessory renal arteries are frequently encountered when patients are evaluated for endovascular abdominal aortic aneurysm repair (EVAR). Some have considered their presence a contraindication to EVAR in fear of endoleak and the end result of renal function. We sought to determine whether the coverage of accessory renal arteries during EVAR was associated with any adverse sequelae. METHODS Retrospective review of the medical records and computed tomographic scans of all patients undergoing EVAR (1998 to 2003) was performed. Note was made of the presence or absence of accessory renal arteries, hypertension, and renal function. Preoperative computed tomographic images were compared with postoperative images to determine the presence of renal infarction. A control group of 26 consecutive patients without accessory renal arteries was used for comparison of the results of EVAR. RESULTS EVAR was performed in 550 patients over the study interval. The mean follow-up was 16 months (range, 1-48 months). The average age was 74 years (range, 57-90 years). Thirty-five patients (6.6%; 32 male and 3 female) were documented to have accessory renal arteries; the average number of accessory arteries was 2 (range, 1-4). Bilateral accessory arteries were present in 13 patients: all but 1 patient (n = 34) had a left-sided accessory renal artery, and 23 had a right-sided accessory renal artery. EVAR was performed with a variety of endografts: AneuRx (n = 10), Talent (n = 7), PowerLink (n = 7), Zenith (n = 5), LifePath (n = 4), and Ancure (n = 2). There were no mortalities. Twelve endoleaks were documented: three type I, eight type II, and one type III. The accessory renal arteries were not implicated in any of the endoleaks, and none of these accessory vessels was embolized before or after EVAR. Seven patients (20%) had renal infarcts associated with EVAR that were noted on follow-up computed tomographic scans. The mean follow-up for patients with segmental infarction was 23 months (range, 8-48 months). Hypertensive status did not change in any patient in whom an accessory renal artery had been covered. The average serum creatinine was 1.08 mg/dL (range, 0.6-1.8 mg/dL) before EVAR in patients with accessory renal arteries covered by an endovascular graft and did not change significantly in response to EVAR. Serum creatinine increased almost twofold in two patients but spontaneously resolved in follow-up. The average preoperative creatinine clearance was 79 mL/min (range, 35-166 mL/min) in patients without an accessory renal artery and was 80 mL/min (range, 35-167 mL/min) after EVAR. The average preoperative creatinine clearance was 67 mL/min (range, 31-137 mL/min) in patients with an accessory renal artery and 68 mL/min (range, 45-83 mL/min) in patients with renal infarcts. None of the patients required temporary or permanent dialysis. There was no difference between control patients and patients with covered accessory renal arteries with respect to hypertensive status, presence of renal infarcts, serum creatinine, or creatinine clearance after EVAR. CONCLUSIONS Occlusion of accessory renal arteries is not associated with clinically significant signs or symptoms, even in patients with mild or moderate renal insufficiency. Sacrifice of accessory renal arteries most commonly does not lead to detectable renal infarction, either clinically or radiographically. When segmental infarction of the kidney does result, it seems to be well tolerated in this group of patients. Accessory renal arteries were not found to contribute to endoleaks and should not be prophylactically embolized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postoperative “Chimney” for Unintentional Renal Artery Occlusion after EVAR

Renal artery obstruction during endovascular repair of abdominal aortic aneurysm using standard device is a rare but life-threatening complication and should be recognized and repaired rapidly in order to maintain renal function. Both conventional surgery and endovascular stenting have been reported. We report a case of late postoperative bilateral "chimney" to resolve a bilateral thrombosis of...

متن کامل

Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, inc...

متن کامل

Renal artery occlusion in the late postoperative period managed with renal artery stenting after endovascular abdominal aortic aneurysm repair and renal function salvage.

Endovascular aneurysm repair (EVAR) of abdominal aorta is a valuable treatment option in selected patients with abdominal aortic aneurysm. Renal artery occlusion is a serious complication after EVAR and may progress to permanent renal injury requiring hemodialysis. In this report, case of unexpected renal artery occlusion after EVAR treated with renal artery stenting in the late postoperative p...

متن کامل

Repair of juxtarenal para-anastomotic aortic aneurysms after previous open repair with fenestrated and branched endovascular stent grafts.

Three patients with juxtarenal para-anastomotic aortic aneurysms after previous open abdominal aortic aneurysm repair were treated with custom-designed fenestrated and branched Zenith endovascular stent grafts. Six renal arteries and two superior mesenteric arteries were targeted for incorporation by graft fenestrations and branches. The fenestration/renal ostium interface was secured with ball...

متن کامل

Successful Endovascular Abdominal Aortic Aneurysm Repair Following Surgical Mobilization of an Accessory Renal Artery in the Setting of Horseshoe Kidney

There are several reported cases of successful endovascular repair of abdominal aortic aneurysm (AAA) in patients with concomitant horseshoe kidney, in which accessory renal arteries were sacrificed. We describe a case of horseshoe kidney and AAA in which a surgical vascular conduit to accessory renal arteries created favorable anatomy for endovascular aneurysm repair (EVAR) while preserving re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular surgery

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2006