Assessment of total retinal blood flow using Doppler Fourier Domain Optical Coherence Tomography during systemic hypercapnia and hypocapnia

نویسندگان

  • Ayda M. Shahidi
  • Sunni R. Patel
  • David Huang
  • Ou Tan
  • John G. Flanagan
  • Chris Hudson
چکیده

The purpose of this study was to investigate changes in total retinal blood flow (RBF) using Doppler Fourier Domain Optical Coherence Tomography (Doppler FD-OCT) in response to the manipulation of systemic partial pressure of CO2 (PETCO2). Double circular Doppler blood flow scans were captured in nine healthy individuals (mean age ± standard deviation: 27.1 ± 4.1, six males) using the RTVue(™) FD-OCT (Optovue). PETCO2 was manipulated using a custom-designed computer-controlled gas blender (RespirAct(™)) connected to a sequential gas delivery rebreathing circuit. Doppler FD-OCT measurements were captured at baseline, during stages of hypercapnia (+5/+10/+15 mmHg PETCO2), return to baseline and during stages of hypocapnia (-5/-10/-15 mmHg PETCO2). Repeated measures analysis of variance (reANOVA) and Tukey's post hoc analysis were used to compare Doppler FD-OCT measurements between the various PETCO2 levels relative to baseline. The effect of PETCO2 on TRBF was also investigated using linear regression models. The average RBF significantly increased by 15% (P < 0.0001) with an increase in PETCO2 and decreased significantly by 10% with a decrease in PETCO2 (P = 0.001). Venous velocity significantly increased by 3.11% from baseline to extreme hypercapnia (P < 0.001) and reduced significantly by 2.01% at extreme hypocapnia (P = 0.012). No significant changes were found in the average venous area measurements under hypercapnia (P = 0.36) or hypocapnia (P = 0.40). Overall, increased and decreased PETCO2 values had a significant effect on RBF outcomes (P < 0.002). In healthy individuals, altered end-tidal CO2 levels significantly changed RBF as measured by Doppler FD-OCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal blood flow measurement with ultrahigh-speed swept-source / Fourier domain optical coherence tomography

Doppler OCT is a functional extension of OCT that provides information on flow in biological tissues. We present a novel approach for total retinal blood flow assessment using ultrahigh speed Doppler OCT. A swept source / Fourier domain OCT system at 1050 nm was used for 3D imaging of the human retina. The high axial scan rate of 200 kHz allowed measuring the high flow velocities in the central...

متن کامل

In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography.

There is considerable interest in new methods for the assessment of retinal blood flow for the diagnosis of eye diseases. We present in vivo normal human volumetric retinal flow measurement using Fourier domain Doppler optical coherence tomography. We used a dual-plane scanning pattern to determine the angle between the blood flow and the scanning beam in order to measure total flow velocity. V...

متن کامل

Doppler optical coherence tomography of retinal circulation.

Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can...

متن کامل

Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT

Doppler OCT provides depth-resolved information on flow in biological tissues. In this article, we demonstrate ultrahigh speed swept source/Fourier domain OCT for visualization and quantitative assessment of retinal blood flow. Using swept laser technology, the system operated in the 1050-nm wavelength range at a high axial scan rate of 200 kHz. The rapid imaging speed not only enables volumetr...

متن کامل

Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography

PURPOSE There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT) to characterize the effects of 100% oxygen breath...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014